© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021408/04/21
Phone +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·
Page 39 of 40
Temperature
influence
±1.5hPa at constant pressure
Voltage supply of
external sensors
Only with model
4.3251.0x.902
Output
2 x Voltage U (Vcc) 12V
(is programmed on request).
Icc (max)
U1
Vcc
+ U1
Vcc
<110mA
Fuse
Polyswitch ca. 140mA
Operating voltage
mains
230V AC ( with 4.3251.00.00x)
115V AC ( with 4.3251.01.00x)
Mains fuse
0.25AT resp. 0,52AT
Low potential voltage 18 ... 28V AC
12 ... 35V DC
Current consumption
Max. 1000mA with 12V DC
Display
Wind velocity
Dimension
m/s, kn, km/h, Bft
WT - display
3-digit LED, height 15mm
Resolution
0.1m/s
0.1kn as of 100kn 1kn
1km/h
1Bft
Wind direction
Resolution
5°
LED’s
72 pieces; 2 x 4mm, Colour: red, green
Follow-up time of the
variation
1 step /sec
WD-delay
= 6sec.
General
Temperature range
-10 ... +50°C
Humidity range
non-condensing
EMV
EN 60945, EN 61000-6-2, EN 61000-6-3
Oscillation
EN 60945, IEC 60068-2-6
Environmental audit
EN 60945
Compass safety
distance
EN 60945
Standard magnetic compass 0.50m
Magnetic steering compass 0.35m
Low potential voltage EN 61010
Casing
Material
aluminium
Dimensions
144 x 144mm depth: 119mm
Weight
1.5kg
Protection class
IP23; EN 60529