7.3 Setting Wind Reference NACOS (COM 4)
* = Delivery status
Setting of the wind reference in the MWV telegram (refer also chap. 8)
7.4 Setting Wind Reference CUSTOMER (COM 5)
* = Delivery status
Setting of the wind reference in the MWV telegram (refer also chap. 8)
7.5 Setting Baud Rate:
* = Delivery status
Attention:
The setting is only accepted after a restart!
Wind reference NACOS
S5
Relative (Rel.) wind *
on
True Wind
off
Wind reference CUSTOMER
S6
Relative (Rel.) wind *
on
True wind
off
Baud rate
S7
S8
1200
on
on
2400
off
on
4800 *
on
off
9600
off
off
ON
1 2 3 4
5
6 7 8
ON
1 2 3 4 5 6
7
8
ON
1 2 3 4 5
6
7 8