Sani-Con Model 300 - Portable Tank “Buddy”
4
www.thetford.com
Electrical Planning
2D
85
86
18G BLU
18G BLU
Fig. 2
Fig. 2
represents recommended wiring configuration. Other wir
-
ing configurations are possible based on your installation.
■
Pump requires a 12-VDC/35 AMP dedicated circuit with 35
AMP breaker or fuse between main bus or battery.
■
Wire size is dependent on distance between pump and
power source. Actual wire sizes should be calculated ac-
cording to installation.
The positive and negative wires should be braided to
prevent radio interference during operation.
NOTICE
While the pump is turned on, verify electrical system
by measuring voltage at motor; (must be 12V).
Improper installation may cause damage to motor or
decrease pump efficiency.
NOTICE
AVIS
AVISO
CAUTION
!
Pump Assembly
T000090C
2A
K4
2B
K1
K3
2C
Included in product
2D
Electrical System
Wire Gauge Size Chart
If Wire Gauge for distance from
source* is:
0-18 feet
(Included)
19-32 Feet
33-50 feet
Circuit
Breaker
12 VOLTS - Install
10 Gauge
8 Gauge
6 Gauge
35 amp
* Distance measured assumes power
and ground wires.
Fig. 3
Ref.
Description
K1
Macerator Pump
K3
Macerator Switch
K4
35A Fuse/Breaker
Ref.
Description
2A
Battery
2B
Relay
2C
Over-Temperature Switch (90°C) normally closed
2D
Ground
Содержание SANICON TURBO 300