INSTALLATION 

 

 

 

 

 

 

 

 

 

 

 
Regulations and Standards 

In your own interest of safety, gas appliances should be installed by competent persons. 
Failure to install the appliance correctly could invalidate any warranty or liability claims. 
This appliance shall be installed in accordance with the manufacturers installation 
instructions, local gas fitting regulations, municipal building codes, AG5601 and any other 
relevant statutory regulations. 

 

Data label.

  

The data label is located on the right hand side front of the oven compartment, behind the 
oven door.  A duplicate data label is supplied to adhere to an accessible area next to the 
appliance.  Ensure that the gas supply is Propane.  This appliance is designed for use with 
Propane gas and should not be converted for use with any other gas. 
 

Ventilation

 

This appliance is suitable for installation into Holiday Homes, Touring Caravans and Boats. 
In all cases the national standards with regard to ventilation for the particular vehicle into 
which the appliance is to be installed must be adhered to.  
The appliance 

MUST

 have a gas escape hole (min size 50mm Ø; max 70mm Ø; or 

shaped hole of equivalent area – 1965 to 3850mm

) in the floor, directly beneath the 

appliance and positioned at the rear as shown in Fig. 3.  The hole 

MUST 

vent to the 

outside and should be baffled to prevent direct draught to the appliance. 

 
Location of Appliance

  

This appliance maybe installed in a kitchen/kitchen diner but NOT in a room containing a 
bath or a shower. LP gas appliances must not be fitted below ground level. e.g. in a 
basement.

 

Position 

CAUTION:  DO NOT LIFT APPLIANCE USING THE DOOR HANDLES 
This appliance must be installed in such a way that the furniture fitted around the unit 
follows the minimum dimensions as shown in Figs. 1. If this cannot be adhered to because 
of design constraints, then the design is deemed permissible providing that the 
temperature rise on the furniture is tested. The temperature rise must not exceed 65C 
above the ambient temperature, or where applicable, must not exceed the maximum 
allowable temperature, to avoid damage, as detailed within the material supplier’s 
specification. 
All combustible materials such as curtains and shelves must be kept well clear of the 
appliance, their installation should meet all relevant local and national standards in force. 

IMPORTANT 
 

  This appliance must be installed into an aperture, sealed off at either side in 

order to prevent draughts from adjoining cupboards/vents. Ensure that air vents 
and gas escape holes are kept clear, holes for cables and pipes must be sized to 
minimize air leakage between compartments. 

  Under no circumstances should the ventilation hole exceed 3850mm

2

  or other 

low level ventilation be located in the compartment, including vents in kickboards. 
Low level vents in adjacent compartments are permitted.  

 

When installing the appliance at ‘Eye’ level, any cupboards beneath the 
appliance 

MUST 

be sealed to prevent a gas escape entering the living area.

 

 

9

Содержание S~OG70000Z

Страница 1: ...LARA WAY CAMPBELLFIELD VIC TEL 03 9358 0700 FAX 03 9357 7060 BUILD IN APPLIANCES FOR USE IN AUSTRALIA USER AND INSTALLATION INSTRUCTIONS PLEASE READ THOROUGHLY AND KEEP FOR FUTURE MODELS S OG70000Z D...

Страница 2: ...2...

Страница 3: ...n 4 Oven 4 Heat input Total heat input 11 1MJ h 5 8MJ h Hotplate Burners N A N A Grill burner heat input 5 3MJ h N A Oven burner heat input 5 8MJ h 5 8MJ h Injector size mm Hotplate Burners N A N A Gr...

Страница 4: ...d have adequate ventilation for complete combustion of gas proper flueing and to maintain temperature of immediate surroundings within safe limits Location This appliance maybe installed in a kitchen...

Страница 5: ...lls to the food being cooked A non toxic smoke may occur when using for the first time so open any windows and turn on mechanical ventilators to help remove the smoke 6 Although the grill does heat up...

Страница 6: ...r the first time so open any windows and turn on mechanical ventilators to help remove the smoke 5 Although the oven does heat up quickly it is recommended that a 10 minutes preheat be allowed The ove...

Страница 7: ...5 2 15 25mins Victoria sandwich 4 2 20 30mins Very rich fruit cake 2 2 Approx 60mins per 500g Puff pastry 8 2 15 30mins Flaky pastry 7 2 15 30mins Shortcrust pastry 6 2 15 55mins Shortbread fingers 3...

Страница 8: ...ked flame leak investigation should be carried out using a leak detector spray Abnormal Operation Any of the following are considered to be abnormal operation and may require servicing Yellow tipping...

Страница 9: ...aybe installed in a kitchen kitchen diner but NOT in a room containing a bath or a shower LP gas appliances must not be fitted below ground level e g in a basement Position CAUTION DO NOT LIFT APPLIAN...

Страница 10: ...pressure is too great Should there be excessive yellow tips resulting in sooting then it is probable that the line pressure is too low and in either case the burners should not be used until the line...

Страница 11: ...ent Disconnect from gas supply 1 Remove appliance from housing 2 Open the oven door and unscrew the 2 screws holding the thermostat probe in position and push the probe back out through the hole in th...

Страница 12: ...d to the right hand side of the cut out Unscrew the injector 8 Thermocouple replacement Disconnect from gas supply 1 Remove appliance from housing 2 Grill burner Unscrew the thermocouple from the cont...

Отзывы: