Introduction to single and tandem systems
In a single unit installation the TSMEB delivers a
water increase of 25°C at flow rates of between
2.8 to 5.5 litres per minute, depending on the
output of the unit installed.
Single unit installation
2.8 to 5.5 Litres per minute @25°C increase
In a tandem installation the 2 TSMEBs deliver a
water increase of 25°C at flow rates of between
5.6 to 11 litres per minute, depending on the
output of the unit installed.
Tandem unit installation
5.6 to 11.0 Litres per minute @25°C increase
In accordance with HSE recommendations the TSMEB is designed to deliver water up to maximum temperature of 50°C. Water
temperatures above 50°C can cause scalding, Care should be taken with children and vulnerable people.
Failure to comply with the installation and operating instructions or improper use voids the warranty. Never remove the unit cover
unless the electricity is turned off at the isolation switch or switchboard. To reduce the risk of electric shock or injury to persons or
property, please follow the installation instructions carefully.
Where the ambient temperatures are likely to drop below 5°C the unit must be drained of water to prevent frozen water damage
occurring. Failure to comply with the installation and operating instructions or improper use voids the warranty.
Important information and warnings!
Key information on single installations
Model
Power
(kW)
Supply
(A)
Supply
cable
Flow L/m
@ +25°C
increase
TSMEB-5
4.8
20
2.5
2.8
TSMEB-6
6.0
25
4.0
3.4
TSMEB-7
7.2
30
4.0
4.1
TSMEB-8
8.4
35
6.0
4.8
TSMEB-10
9.6
40
6.0
5.5
Key information on tandem installations
Model
Power
(kW)
Supply
(A)
Total Supply
(A)
Supply
cable
Flow L/m
@ +25°C
increase
TSMEB-5
(x2)
4.8 ea
20 (x2)
40
2.5
5.6
TSMEB-6
(x2)
6.0 ea
25 (x2)
50
4.0
6.8
TSMEB-7
(x2)
7.2 ea
30 (x2)
60
4.0
8.2
TSMEB-8
(x2)
8.4 ea
35 (x2)
70
6.0
9.6
TSMEB-10
x(2)
9.6 ea
40 (x2)
80
6.0
11.0