Important information and warnings!

Product registration

To the installer:

Please fill in both the installer details and product details tables below to ensure that the home or 
property owner has all the information they need to register the product and also get technical 
help from ThermoSphere should the need arise.

The installer must complete the information on this page and hand a copy to the home owner to keep 
for their records. The home owner will require this information in order to register the product and to 
make a warranty claim should the need arise. Proof of purchase is also required for warranty claims.

Installer details

Name:

Company:

Email:

Phone:

Address:

Postcode:

Date of installation:

Proof of purchase: Yes / No

Signature:

Product details

Part no

Serial no

Supply 

circuit max 

current 
(Amps)

Supply 

cable 

diameter 

(mm)

No. of 

taps/

showers 

supplied

Incoming 

water 

temp (°C)

Set water 

temp. (°C)

System 

flushed 

and 

primed?

Single or 

Tandem 

install?

The stock no of the 

product. You can 

find this on the label 

under the unit.

The serial no of the 

product. You can 

find this on the label 

under the unit.

What is the max 

current of the 

RCBO in Amps?

What is the 

diameter of the 

cable in the 

supply circuit?

How many taps, 

showers or 

other outlets are 

supplied?

Use a 

thermometer 

to measure the 

temp of the 

water going 

into the unit.

What is the water 

temperature set on 

the control panel 

on the front of the 

unit?

Has the product 

been flushed 

and primed 

before leaving 

site?

Is it a single or 

tandem unit 
installation?

Yes / No

Single / 

Tandem

Yes / No

Single / 

Tandem

Yes / No

Single / 

Tandem

To the home/property owner:

Use this information to register your 
product online at thermosphere.com.
Ensuring you have all of the information 
on this page will help with any technical 
support that you may need, or a warranty 
claim should the need arise.

Scan the QR code or visit: 

www.thermosphere.com/water-heating/
micro-electric-boilers/register

Содержание TSMEB-10

Страница 1: ...HEATING WATER MICRO ELECTRIC BOILER Live well INSTALL GUIDE...

Страница 2: ...f your work Just scan the QR code or search online for ThermoSphere CONNECT and fill in the form Nice and easy After you sign up instantly start uploading your receipts to gain your rewards Join in 60...

Страница 3: ...Installation options 8 Specifications 9 Flow rates 10 Installation procedure 11 Mounting to the wall 12 Electrical terminals and connections 13 Wiring diagrams for single and tandem installations 14 P...

Страница 4: ...ThermoSphere Bridge House Pattenden Lane Marden Kent TN12 9QJ United Kingdom hello thermosphere com 0800 0195899 2 The process will then follow the ThermoSphere Product Warranty Flow Chart to assess w...

Страница 5: ...eferably be installed in a vertical position on an internal wall or in an internal cupboard or space If the safety rules or the instructions outlined in this manual are not followed correctly the unit...

Страница 6: ...g 2 TSMEB Top Cover 13 TSMEB Inlet Filter 3 TSMEB Heat Sink 14 PCB Terminal Block 4 TSMEB Flow Rate Sensor 15 Electric Mains Supply Cable Gland 5 TSMEB Temperature Sensor Receptacle Cable and Plug Ass...

Страница 7: ...s or improper use voids the warranty Never remove the unit cover unless the electricity is turned off at the isolation switch or switchboard To reduce the risk of electric shock or injury to persons o...

Страница 8: ...ls and labour It also eliminates wasted water and wasted energy by delivering water at the correct temperature within seconds Point of use with cold feeds or mixer taps TSMEBs can be installed to supp...

Страница 9: ...d inside only Ambient temperatures 5 C Drain unit if the ambient temperature is likely to drop below 5 C Standards CE Warranty 3 years Electrical specifications Model TSMEB 5 TSMEB 6 TSMEB 7 TSMEB 8 T...

Страница 10: ...11 4 6 9 13 8 8 16 9 2 17 25 C 2 8 5 6 3 4 6 8 4 1 8 2 4 8 9 6 5 5 11 35 C 2 4 2 5 5 2 9 5 8 3 4 6 8 3 9 7 8 45 C 1 5 3 1 9 3 8 2 3 4 6 2 7 5 4 3 1 6 2 Flow rates and energy use with input water at 5...

Страница 11: ...supplying the 240VAC electrical mains to the TSMEB are turned OFF 7 Carefully replace the plug and cable connecting the display PCB LED indicator to the PCBA 8 Connect a water pressure limiting valve...

Страница 12: ...d the mains supply cable gland fitting hole must not be drilled out Any holes drilled within these areas the sides of the unit or opening out the cable gland fitting hole will render the unit inoperab...

Страница 13: ...o thermosphere com 13 Electrical terminals and connections 1 2 3 4 5 6 Electric supply cable gland Printed circuit board assembly PCBA Terminal block Display PCB PCBA reset button Display PCB plug and...

Страница 14: ...cause an earth leakage detection Error code FC With tandem installations both units must be fitted with their own respective RCBO and an isolation switch in line with the xed wiring to each electrica...

Страница 15: ...talled must not be a non return valve If the water heater is supplying a dishwasher or washing machine a water hammer arrestor must be installed on the outlet side of the water heater Water inlet and...

Страница 16: ...dy for use Step 1 Flush Flushing is required to clear the unit of plumbing debris that may have collected in the piping during installation This is done with the electric power supply turned off Flush...

Страница 17: ...slow or fast flashing GREEN Fast flashing GREEN Unit is operating and water is being heated Flashing RED continuously Irresolvable error and mechanical lockout Unit will no longer operate until the e...

Страница 18: ...mal operation No error 01 Fast flashing GREEN Heating normal operation No error N A Solid ORANGE Water conductivity too low No error N A Solid ORANGE In priming mode No error A4 Flashing RED Operating...

Страница 19: ...D indicators on the PCB will be illuminated when the unit is in standby running or in error mode 2 Press the PCBA reset button If the RED LED remains either flashing or illuminated and error condition...

Страница 20: ...ps showers supplied Incoming water temp C Set water temp C System flushed and primed Single or Tandem install The stock no of the product You can find this on the label under the unit The serial no of...

Страница 21: ...0800 019 5899 hello thermosphere com 21 Notes...

Страница 22: ...0800 019 5899 hello thermosphere com 22 Notes...

Страница 23: ...23 135mm 285mm Installation hole marking template 170mm...

Страница 24: ...Thermogroup Ltd Bridge House Pattenden Lane Marden TN12 9QJ E OE Thermogroup Ltd 2022 0800 019 5899 hello thermosphere com www thermosphere com TSMEBIG_1121_v1 2 Live well...

Отзывы: