7.1 OPERATIONAL MESSAGES
On power-up, machine identification and version number will momentarily appear on the
LCD display. The temperature wait message shown at the main display will be replaced by
the continuous count or the daily count when the temperature is within 15 degrees Fahr-
enheit or 7 degrees Celsius of the set point temperature. The operator can change options
during the warm-up period.
Temperature Controller Messages
The temperature controller will be interrogated and if a fault is detected one of the following
messages will appear:
Line 1
Meaning/Response
Heater Failure
Logic board
Temperature control board is either bad or
unplugged
Heater Failure
Heat Sensor
Temperature sensor is either bad or discon-
nected
Heater Failure
Slow heat rise
Heater is bad or disconnected; or tempera-
ture sensor
is bad, disconnected, or shorted
Heater Failure
High temperature
Relay is bad or shorted; temperature sensor
is bad or
shorted; or bad connections
Heater failure
Unknown
Contact Thermopatch
Seal Switch ERR
Display when touch guard is activated.
This indicates the seal down switch was not
activated
During a seal cycle if the top platen did not
come down
Check seal down switch and wiring
TOUCH GUARD FAULT
This indicates the guard was hit. Press the
CLEAR Button.
Содержание Deco-Print DP2000T
Страница 13: ...thermopatch com 13 Step 5 Refer to below Place flange assemblies Item A on supply and take up shafts Item B...
Страница 14: ...thermopatch com 14...
Страница 15: ...thermopatch com 15...
Страница 41: ...thermopatch com 41 Drawing 15 Electronics Module Drawing 16 Main Electronics Module...
Страница 42: ...thermopatch com 42 Drawing 17 AC Harness...
Страница 43: ...thermopatch com 43 Drawing 18 DC Harness...