Recommendation: 

We recommend that the operation of boilers without weather-compensated regulation be controlled at least by a 

basic room thermostat. The room temperature is constant and it keeps the boiler in longer operation modes. It is 
also recommended to set the boiler thermostat for 60 ºC in autumn and spring and for 80 ºC in winter. It is 
advisable to use the inbuilt weather-compensated regulation that can be also complimented by a room thermostat, 
as it is suggested bellow. 

These expansion regulation types are 

not delivered

 with the boiler. 

 

 

STARTING THE BOILER 

Only a service technician certified by the manufacturer is authorised to put the boiler in operation for the 
very first time.  

Before the boiler is ignited for the first time, it is necessary to take the following measures: 

™

 

Make sure that the heating system is filled with water and the boiler properly deaerated. 

™

 

Make sure that all the valves are open. 

™

 

Open the gas cock and check the tightness of the gas distribution system in the boiler. 

These are the steps to be taken when igniting the boiler for the first time: 

™

 

Set the adjusting revolving knob of the outlet temperature at the maximum. 

™

 

Plug the cable into the socket and start the boiler by turning the mode switch. 

™

 

Turn the mode switch for a short time to malfunction-unblock position, so that the boiler gets automatically 

ignited (this happens only if the gas inlet has been deaerated). 

™

 

Check whether all safety thermostats and control elements are working properly. 

™

 

Check the setting-up of the boiler’s output range and, if necessary, adjust the setting according to the 
requirements of the heated premises. 

 
Warning: 

The setting of boiler’s output range and other parameters must follow the manufacturer’s technical 

specifications. Any overloading or improper operations of the boiler can cause damage to its components! The 
components damaged in this way are not covered by the guarantee.
 

 

DISCONNECTING THE BOILER 

       For shorter periods, the boiler can be switched off by the mode switch or by the switch on the room thermostat.  
For long-term disconnection outside the heating season (e.g. during the summer holiday) it is advisable to close the 
gas gas cock. 

6.  INSTRUCTIONS FOR OPERATION AND MAINTENANCE 

 

 

OPERATING THE BOILER 

 

The boiler may be operated only by a person older than 18 years. 
 

 

Manometer 

Knob for 
DHW 
temperature 
setting 

Knob for 
heating 
temperature 
setting 

Mode 
switch 

LCD display 

Service buttons 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 

 

9

 

™

 

Service buttons 

– are used for diagnostics and setting-up of the boiler parameters

 

Содержание Therm 28 KD

Страница 1: ...Manual for Installation and Maintenance of Condensing Boilers Therm 28 KD KDZ KDC...

Страница 2: ...INSTRUCTIONS FOR OPERATION AND MAINTENANCE 9 OPERATING THE BOILER 9 7 DIMS03 TH01 MODULATION ELECTRONICS 11 8 SIT 848 SIGMA GAS FITTING 14 9 GUARANTEE AND LIABILITY FOR DEFECTS 15 10 GRAPHS OF THE US...

Страница 3: ...ular burner and a modified pipiline conducting the air gas mixture The approriate rationing of the air gas mixture and its mixing is ensured by a mixer and a special gas fitting The latter contains a...

Страница 4: ...perations and the electric circuits participating in the ignition of the burner Important The type of supply of the ionizing current is determined by the neutral It is therefore crucial that the neutr...

Страница 5: ...stem excess pressure bar 0 8 0 8 0 8 Max DHW inlet pressure bar 6 Min DHW inlet pressure bar 0 5 Max heating water outlet temperature o C 80 80 80 Coaxial flue exhaust diameter mm 60 100 60 100 60 100...

Страница 6: ...materials polyurethane polystyrene polyethylene PVC etc Important No flammable objects can be placed closer than at the safe distance from the boiler the minimum distance of the appliance from flamma...

Страница 7: ...by a professional company with valid certification and its professional certified employees and according to the approved documentation for gas fitting The gas regulator is not to be fitted in front...

Страница 8: ...ng system is filled with water the boiler must be unplugged i e the plug must be out of the socket The recommended heating water pressure ranges from 1 to 1 5 bar when the system is cold The heating s...

Страница 9: ...imum Plug the cable into the socket and start the boiler by turning the mode switch Turn the mode switch for a short time to malfunction unblock position so that the boiler gets automatically ignited...

Страница 10: ...ay The meaning of the used symbols temperature failure modes and service data in digital numbers DHW regime DHW temperature displayed heating mode heating temperature displayed boiler burning temperat...

Страница 11: ...l value 6 Offset of the weather compensation curve the numerical value 7 Running speed of the ventilator without a symbol the numerical value x 10 8 Back to the standard indication Once the setting ha...

Страница 12: ...t this moment the burning in the boiler is stopped while the circulation pump is still in operation and the time limit of the repeated ignition is put into operation the service setting of the time li...

Страница 13: ...t the starting power circa 10 sec after the boiler s ignition and increases the boiler output at the maximum level so that the outlet temperature that was previously set by the user can be achieved as...

Страница 14: ...the air gas ratio air pressure signal inlet module for measuring the outlet gas pressure setting of the starting point of regulation SIT 848 SIGMA is a gas fitting with proportional regulation air ga...

Страница 15: ...and maintenance The guarantee covers neither situations caused by non standard conditions in the distribution network voltage fluctuation and overvoltage peaks gas pressure and purity etc nor defects...

Страница 16: ...28 KDC KDZ 0 0 50 0 100 0 150 0 200 0 250 0 300 0 350 0 400 0 450 0 500 0 0 4 0 6 0 8 1 1 2 Water through flow m 3 h Outlet excess pressure mbar Wilo 3 Grunfos 3 Warning The curves of the applicable c...

Страница 17: ...11 Wiring connect of the THERM 28 KD boilers with the DIMS03 TH01 automatics 17...

Страница 18: ...12 Wiring connect of the THERM 28 KDC boilers with the DIMS03 TH01 automatics 18...

Страница 19: ...19 13 Wiring connect of the THERM 28 KDZ boilers with the DIMS03 TH01 automatics...

Страница 20: ...re no 23640 Ventilator MVL 130 24 store no 22141 Ionizing electrode store no 20342 Mixer SIT store no 40390 Gas valve SIT store no 40848 Expansion vessel 7l store no 22168 Seal pipe store no 23405 Blo...

Страница 21: ...noni condensation device store no 23821 Ignition electrode store no 23640 Ventilator MVL 130 24 store no 22141 Ionising electrode store no 20342 Mixer SIT store no 40390 Gas valve SIT store no 40848 E...

Страница 22: ...izing electrode strore no 20342 Mixer SIT store no 40390 Gas valve SIT store no 40848 Expansion vessel 7l store no 22168 Seal pipe store no 23405 Blocking thermostat store no 40035 Transformer 220V 24...

Страница 23: ...17 HANGING THERM 28 KD KDZ KDC BOILERS I 23...

Страница 24: ...sely to each other not further than 50 cm that they are exposed to the same climatic conditions C43 Separated connection to two pipelines within the same shaft The outlet of both shafts is either conc...

Страница 25: ...the requirements of valid norms and regulations The product packaging should be taken to the paper disposal area while the package film should be disposed in the public containers in which the plastic...

Страница 26: ...e authorized person 202 THERM 28 KD THERM 28 KDC THERM 28 KDZ certificate for type testing according to the EC directives for gas appliances 90 396 EEC No E 30 00712 02 THERM 28 KD THERM 28 KDC THERM...

Отзывы: