E05 

The DHW sensor is damaged (relates only to KDC boilers) 

E06 

Malfunction concerning the exceeded limit set for the heating 
water temperature (blocking thermostat) 

E07 

The outside temperature sensor is damaged (relates to the weather-
compensated regulation) 

E08 

Malfunction of the ventilator (feedback speed signal) 

E09 

Malfunction of the ventilator (the running speed outside the 
control range) 

E10 

Malfunction of the ventilator (it keeps rotating at the “stop” 
position) 

E12 

Insufficient flow of the heating water (after repeated tests)  

 
 
 
 

 

 

Information indicated on the display: 

By using the service buttons  (the buttons placed at the ends; the arrow with the right hand indication “ ” – pacing 
forward, the arrow with the left hand indication “ ”– pacing backward) it is possible to display the boiler’s 
parametres in the following order: 
 
1.

 

Set temperature of heating water  

(  + °C + the numerical value is blinking) 

2.

 

Actual temperature of heating water  

(  + °C + the numerical value). 

3.

 

Set DHW temperature*  

(  + °C + the numerical value is blinking). 

4.

 

Actual DHW temperature * 

(  + °C + the numerical value). 

5.

 

Outside temperature**  

(  + °C + the numerical value). 

6.

 

Offset of the weather-compensation curve**   (  + the numerical value). 

7.

 

Running speed of the ventilator 

(without a the numerical value x 10) 

8.

 

Back to the standard indication 

 

 
 
Once the setting has been done, the numerical value and the corresponding symbol appear on the display for 10 
seconds. Then the standard mode sets in again. 
 

(*) –  

The KD and KDZ boilers do not display the numerical values  

 

 

(on the display appears “- -“) 

(**) – These parameters are displayed only when the weather-compensated regulation of the heating has 

been used (the parameter switch is in the corresponding position, the outside temperature sensor 
is connected and undamaged). 

 
If you operate the boiler by the CX51MC room regulator with the IU02 interface the on-going Open-Therm 
communication is signalled in the corners of the display by upwards pointed arrows: “   ”, in the case of cascade 
communication (IU04 and IU05) the arrows point downwards: “   ”. 
 
 

 7.  DIMS03-TH01 MODULATION ELECTRONICS 
 
 
Dip switch – sets the type of the boiler and its parameters  
 

 

DS1-DHW 

DS2-ext. sensor 

DS3-cascade 

DS4 

DS5 

DS6 

OFF 

Supply tank 

Without ext. sensor 

slave 

 

 

 

ON 

Through-flow 

With ext. sensor 

master 

 

 

 

 
Factory setting: DS1 – according to the type of boiler; DS2 – OFF (mode 1.1), DS3 – OFF; pump running-out – 
50% = 5 min; anticycling delay - 50% = 5 min.
 
 
 
 
Operation description: 

 11

 

Содержание Therm 28 KD

Страница 1: ...Manual for Installation and Maintenance of Condensing Boilers Therm 28 KD KDZ KDC...

Страница 2: ...INSTRUCTIONS FOR OPERATION AND MAINTENANCE 9 OPERATING THE BOILER 9 7 DIMS03 TH01 MODULATION ELECTRONICS 11 8 SIT 848 SIGMA GAS FITTING 14 9 GUARANTEE AND LIABILITY FOR DEFECTS 15 10 GRAPHS OF THE US...

Страница 3: ...ular burner and a modified pipiline conducting the air gas mixture The approriate rationing of the air gas mixture and its mixing is ensured by a mixer and a special gas fitting The latter contains a...

Страница 4: ...perations and the electric circuits participating in the ignition of the burner Important The type of supply of the ionizing current is determined by the neutral It is therefore crucial that the neutr...

Страница 5: ...stem excess pressure bar 0 8 0 8 0 8 Max DHW inlet pressure bar 6 Min DHW inlet pressure bar 0 5 Max heating water outlet temperature o C 80 80 80 Coaxial flue exhaust diameter mm 60 100 60 100 60 100...

Страница 6: ...materials polyurethane polystyrene polyethylene PVC etc Important No flammable objects can be placed closer than at the safe distance from the boiler the minimum distance of the appliance from flamma...

Страница 7: ...by a professional company with valid certification and its professional certified employees and according to the approved documentation for gas fitting The gas regulator is not to be fitted in front...

Страница 8: ...ng system is filled with water the boiler must be unplugged i e the plug must be out of the socket The recommended heating water pressure ranges from 1 to 1 5 bar when the system is cold The heating s...

Страница 9: ...imum Plug the cable into the socket and start the boiler by turning the mode switch Turn the mode switch for a short time to malfunction unblock position so that the boiler gets automatically ignited...

Страница 10: ...ay The meaning of the used symbols temperature failure modes and service data in digital numbers DHW regime DHW temperature displayed heating mode heating temperature displayed boiler burning temperat...

Страница 11: ...l value 6 Offset of the weather compensation curve the numerical value 7 Running speed of the ventilator without a symbol the numerical value x 10 8 Back to the standard indication Once the setting ha...

Страница 12: ...t this moment the burning in the boiler is stopped while the circulation pump is still in operation and the time limit of the repeated ignition is put into operation the service setting of the time li...

Страница 13: ...t the starting power circa 10 sec after the boiler s ignition and increases the boiler output at the maximum level so that the outlet temperature that was previously set by the user can be achieved as...

Страница 14: ...the air gas ratio air pressure signal inlet module for measuring the outlet gas pressure setting of the starting point of regulation SIT 848 SIGMA is a gas fitting with proportional regulation air ga...

Страница 15: ...and maintenance The guarantee covers neither situations caused by non standard conditions in the distribution network voltage fluctuation and overvoltage peaks gas pressure and purity etc nor defects...

Страница 16: ...28 KDC KDZ 0 0 50 0 100 0 150 0 200 0 250 0 300 0 350 0 400 0 450 0 500 0 0 4 0 6 0 8 1 1 2 Water through flow m 3 h Outlet excess pressure mbar Wilo 3 Grunfos 3 Warning The curves of the applicable c...

Страница 17: ...11 Wiring connect of the THERM 28 KD boilers with the DIMS03 TH01 automatics 17...

Страница 18: ...12 Wiring connect of the THERM 28 KDC boilers with the DIMS03 TH01 automatics 18...

Страница 19: ...19 13 Wiring connect of the THERM 28 KDZ boilers with the DIMS03 TH01 automatics...

Страница 20: ...re no 23640 Ventilator MVL 130 24 store no 22141 Ionizing electrode store no 20342 Mixer SIT store no 40390 Gas valve SIT store no 40848 Expansion vessel 7l store no 22168 Seal pipe store no 23405 Blo...

Страница 21: ...noni condensation device store no 23821 Ignition electrode store no 23640 Ventilator MVL 130 24 store no 22141 Ionising electrode store no 20342 Mixer SIT store no 40390 Gas valve SIT store no 40848 E...

Страница 22: ...izing electrode strore no 20342 Mixer SIT store no 40390 Gas valve SIT store no 40848 Expansion vessel 7l store no 22168 Seal pipe store no 23405 Blocking thermostat store no 40035 Transformer 220V 24...

Страница 23: ...17 HANGING THERM 28 KD KDZ KDC BOILERS I 23...

Страница 24: ...sely to each other not further than 50 cm that they are exposed to the same climatic conditions C43 Separated connection to two pipelines within the same shaft The outlet of both shafts is either conc...

Страница 25: ...the requirements of valid norms and regulations The product packaging should be taken to the paper disposal area while the package film should be disposed in the public containers in which the plastic...

Страница 26: ...e authorized person 202 THERM 28 KD THERM 28 KDC THERM 28 KDZ certificate for type testing according to the EC directives for gas appliances 90 396 EEC No E 30 00712 02 THERM 28 KD THERM 28 KDC THERM...

Отзывы: