Combustion  air  feed,  including  induced  venting,  is  ensured  by  external  coaxial  piping  which  passes  either 

horizontally through the perimeter wall or vertically through the roof construction into the free space. The piping 
needs  be  installed  in  a  manner  which  will  prevent  (due  to  low  combustion  product  temperature)  freezing  of  the 
venting  outlet.  Vertical  piping  must  be  therefore  unconditionally  terminated  in  a  horizontal  roof  vent  slightly 
slanting from the register to the boiler. 
  

A  water  delivery  Grundfos  or  Wilo  pumps  ensuring  the  flow  of  water  through  the  boiler  are  inbuilt  at  the 

recuperative  water  inlet.  Sufficient  flow  of  heating  water  is  monitored  by  a  flow  switch  integrated  in  the  multi-
purpose  GRF 3  collector  together  with  the  bypass,  valve  for  charging  the  heating  system  from  the  service  water 
inlet  (or  potentially  from  an  external  connection)  and  by  a  discharge  valve.  The  collector  is  also  connected  to  a 
safety valve ensuring the protection of the boiler against over-pressure. 
  

THERM  17  KDZ  boilers  are  additionally  fitted  with  a  motoric  intercepting  valve  installed  prior  to  the 

heating water outlet from the boiler separating the HSW and heating system heating functions. 
  

The control panel is entirely made of plastic. The control elements are located on the front side (for further 

details see the regulations for operation). A single-board DIMS03-TH01 automatics is integrated inside comprising 
electronic circuits for the burner ignition and microprocessor control of the boiler's functions. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Therm 17 KD

Страница 1: ...Instructions for installation and use of condensing boilers Therm 17 KD KDZ KDZ 5...

Страница 2: ...NS FOR OPERATION AND MAINTENANCE 10 BOILER OPERATION 10 7 MODULATING ELECTRONICS DIMS03 TH01 12 8 GAS FITTING SIT 848 SIGMA 15 9 WARRANTY AND RESPONSIBILITY FOR DEFECTS 16 10 GRAPH OF POSSIBLE HEATING...

Страница 3: ...LERS THERM 17 KD gas boiler is composed of a carry frame to which all operational components of the boiler are attached Giannoni compact condensing body which conjugates the combustion chamber and bur...

Страница 4: ...ored by a flow switch integrated in the multi purpose GRF 3 collector together with the bypass valve for charging the heating system from the service water inlet or potentially from an external connec...

Страница 5: ...0 Diameter of the coaxial venting mm 60 100 60 100 60 100 Mean combustion product temperature o C 50 50 50 Combustion product flow by weight natural gas g s 1 2 1 9 8 2 1 9 8 2 1 9 8 Max noisiness acc...

Страница 6: ...the ambient temperatures within the range of 5 to 35 C and maximum relative humidity of 80 Objects in the sense of Czech standard SN 06 10 08 classified according to Czech standard SN 73 08 23 must n...

Страница 7: ...er expansion vessel capacity it is necessary to install another expansion vessel in the system CONDENSED WATER DRAINAGE The boiler is fitted with a running trap syphon which must be filled with approx...

Страница 8: ...luding the outlet distance pieces piping fittings designed for the supplied boiler type These boiler components are supplied separately depending on the type and concrete installation conditions the b...

Страница 9: ...re regulation e g Honeywell CM 707 CM 907 or Electrobock PT 21 PT 30 etc An outdoor THERM Q01 sensor is supplied by Thermona for an expedient equitherm regulation An intelligent THERM RC 03 programmab...

Страница 10: ...persons over 18 years of age Service buttons are designed for boiler diagnostics and parameter settings Heating temperature setting regulator for user setting of the output temperature of water in the...

Страница 11: ...setting is finished the set temperature value will be indicated for the following roughly 5 seconds The actual temperature of the respective operating mode is indicated by the subsequent permanent dis...

Страница 12: ...1 HSW DS2 outdoor sensor DS3 cascade DS4 DS5 DS6 OFF tank without the outdoor sensor slave ON flow with the outdoor sensor master Default setting DS1 depends on the boiler type DS2 OFF mode 1 1 DS3 OF...

Страница 13: ...n of the equitherm curve displacement in the range of 15 C of the heating water by the heating water temperature regulator on the control panel The equitherm curve is modified for a standard heating s...

Страница 14: ...m the combustion chamber Regular pump start up if boiler does not operate for 30 seconds after 24 hours of inactivity Regular contact making of the intercepting valve for 10 seconds after 24 hours of...

Страница 15: ...output i e minimum ventilator speed is already set By tightening the screw the amount of gas in the mixture increases 2 Setting the air gas mixture ratio To do this use the regulatory screw of the gas...

Страница 16: ...llation of the el voltage chiefly excess voltage peaks gas pressure and purity etc defects of the appliances outside the boiler which affect its function inappropriate venting impurities in the combus...

Страница 17: ...ssure of THERM 17 KDZ 17 KDZ 5 0 0 50 0 100 0 150 0 200 0 250 0 300 0 350 0 400 0 450 0 500 0 0 4 0 6 0 8 1 1 2 Water flow m3 h Outlet over pressure mbar Wilo 3 Grunfos 3 Warning The curves of possibl...

Страница 18: ...18 11 El diagram of THERM 17 KD connection with the DIMS03 TH01 automatics...

Страница 19: ...19 12 El diagram of THERM 17 KDZ KDZ 5 boilers connection with the DIMS03 TH01 automatics...

Страница 20: ...40997 Grundfos pump st No 41367 Syphon st No 21059 1 Conjugated fitting GRF 3 st No 26072 Safety valve st No 40302 Ventilator RG130 0800 3612 031111 st No 42195 Mixer AGU3 645 A 109 st No 42197 Blocki...

Страница 21: ...ansion vessel st No 22168 Transformator 220V 24V st No 24477 Gas valve SIT st No 40997 Grundfos pump st No 41367 Siphon st No 21059 1 Conjugated fitting GRF 3 st No 26072 Safety valve st No 40302 16 T...

Страница 22: ...tor 220V 24V st No 24477 Mixer AGU3 645A109 st No 42197 Ventilator RG130 0800 3612 st No 42195 Safety thermostat st No 40035 Gas valve SIT st No 40997 Three way valve st No 21053 Grundfos pump st No 4...

Страница 23: ...71 90 100 80 177 O60 425 800 160 800 1 Recuperative water inlet G 3 4 external thread 2 Heating water outlet 3 Gas inlet G 1 2 external thread 4 Service water inlet G 1 2 external thread 5 Service wat...

Страница 24: ...either concentric or located in such small distance within 50cm that it is subject to the same meteorological conditions C43 Separate connection to the two pipes of a common shaft The outlet can be ei...

Страница 25: ...ompliant with the requirements specified in Section 10 of the Act No 185 2001 Coll and Section 6 of the Act No 477 2001 Coll The product package is normally disposed of in a scrap paper collecting cen...

Страница 26: ...o the EC notified body No 1015 THERM 17 KD THERM 17 KDZ THERM 17 KDZ 5 test certificate of type according to the EC Directive on appliances burning gaseous fuel 90 396 EEC No E 30 00571 07 as of Augus...

Отзывы: