background image

 

26 

 
 

 

 

 

 
 

 

PRODUCT QUALITY AND COMPLETENESS 

CERTIFICATE 

 

THERM gas condensing boiler 

 

 

 

 

 

  

Type designation: 

THERM 17  

 

 

 

  

 
Serial number: 
 
 

The appliance conforms to requirements of the aforementioned directives, technical regulations and standards 
and  its  operation  is  safe  under  conditions  of  regular  use.  Measures  are  taken  assuring  that  this  appliance 
introduced  to  the  market  conforms  with  the  technical  documentation  and  basic  technical,  safety  and  sanitary 
requirements.  

 
The described condensing boiler variations were assessed and authorized by the 

Engineering Test Institute 

in Brno, 

the EC notified body No. 1015

:  

 

THERM 17 KD

THERM 17 KDZ, THERM 17 KDZ 5

 – test certificate 

of type

 according to the EC Directive 

on appliances burning gaseous fuel 

90/396/EEC

 

No. E-30-00571-07 

as of August, 2007. 

 
THERM  17  KD

THERM  17  KDZ,  THERM  17  KDZ  –

  test  certificate 

of  type

  according  to  EC  Directive  on

 

boiler efficiency

 

92/42/EEC 

No.

 E-30-00572-07 

as of August, 2007. 

 
Gas condensing boilers of the 

THERM 17 KD

THERM 17 KDZ and THERM 17 KDZ 5 

series bear a 

trademark of an 

"Environmentally-friendly product No. 11- 32"

. It thus ranks among products with minimum 

adverse effects on the environment. 
 
 

Technical inspection 

 
 
date: ..................................................................................... 
 
 
 
 
stamp and signature: ....................................................................... 
 
 
 

            

THERMONA, spol. s r. o. 

Stará osada 258, Zastávka u Brna, 664 84, Czech Republic 

Phone: +420 544 500 505, +420 544 500 511 

Fax: +420 544 500 506

 

Содержание Therm 17 KD

Страница 1: ...Instructions for installation and use of condensing boilers Therm 17 KD KDZ KDZ 5...

Страница 2: ...NS FOR OPERATION AND MAINTENANCE 10 BOILER OPERATION 10 7 MODULATING ELECTRONICS DIMS03 TH01 12 8 GAS FITTING SIT 848 SIGMA 15 9 WARRANTY AND RESPONSIBILITY FOR DEFECTS 16 10 GRAPH OF POSSIBLE HEATING...

Страница 3: ...LERS THERM 17 KD gas boiler is composed of a carry frame to which all operational components of the boiler are attached Giannoni compact condensing body which conjugates the combustion chamber and bur...

Страница 4: ...ored by a flow switch integrated in the multi purpose GRF 3 collector together with the bypass valve for charging the heating system from the service water inlet or potentially from an external connec...

Страница 5: ...0 Diameter of the coaxial venting mm 60 100 60 100 60 100 Mean combustion product temperature o C 50 50 50 Combustion product flow by weight natural gas g s 1 2 1 9 8 2 1 9 8 2 1 9 8 Max noisiness acc...

Страница 6: ...the ambient temperatures within the range of 5 to 35 C and maximum relative humidity of 80 Objects in the sense of Czech standard SN 06 10 08 classified according to Czech standard SN 73 08 23 must n...

Страница 7: ...er expansion vessel capacity it is necessary to install another expansion vessel in the system CONDENSED WATER DRAINAGE The boiler is fitted with a running trap syphon which must be filled with approx...

Страница 8: ...luding the outlet distance pieces piping fittings designed for the supplied boiler type These boiler components are supplied separately depending on the type and concrete installation conditions the b...

Страница 9: ...re regulation e g Honeywell CM 707 CM 907 or Electrobock PT 21 PT 30 etc An outdoor THERM Q01 sensor is supplied by Thermona for an expedient equitherm regulation An intelligent THERM RC 03 programmab...

Страница 10: ...persons over 18 years of age Service buttons are designed for boiler diagnostics and parameter settings Heating temperature setting regulator for user setting of the output temperature of water in the...

Страница 11: ...setting is finished the set temperature value will be indicated for the following roughly 5 seconds The actual temperature of the respective operating mode is indicated by the subsequent permanent dis...

Страница 12: ...1 HSW DS2 outdoor sensor DS3 cascade DS4 DS5 DS6 OFF tank without the outdoor sensor slave ON flow with the outdoor sensor master Default setting DS1 depends on the boiler type DS2 OFF mode 1 1 DS3 OF...

Страница 13: ...n of the equitherm curve displacement in the range of 15 C of the heating water by the heating water temperature regulator on the control panel The equitherm curve is modified for a standard heating s...

Страница 14: ...m the combustion chamber Regular pump start up if boiler does not operate for 30 seconds after 24 hours of inactivity Regular contact making of the intercepting valve for 10 seconds after 24 hours of...

Страница 15: ...output i e minimum ventilator speed is already set By tightening the screw the amount of gas in the mixture increases 2 Setting the air gas mixture ratio To do this use the regulatory screw of the gas...

Страница 16: ...llation of the el voltage chiefly excess voltage peaks gas pressure and purity etc defects of the appliances outside the boiler which affect its function inappropriate venting impurities in the combus...

Страница 17: ...ssure of THERM 17 KDZ 17 KDZ 5 0 0 50 0 100 0 150 0 200 0 250 0 300 0 350 0 400 0 450 0 500 0 0 4 0 6 0 8 1 1 2 Water flow m3 h Outlet over pressure mbar Wilo 3 Grunfos 3 Warning The curves of possibl...

Страница 18: ...18 11 El diagram of THERM 17 KD connection with the DIMS03 TH01 automatics...

Страница 19: ...19 12 El diagram of THERM 17 KDZ KDZ 5 boilers connection with the DIMS03 TH01 automatics...

Страница 20: ...40997 Grundfos pump st No 41367 Syphon st No 21059 1 Conjugated fitting GRF 3 st No 26072 Safety valve st No 40302 Ventilator RG130 0800 3612 031111 st No 42195 Mixer AGU3 645 A 109 st No 42197 Blocki...

Страница 21: ...ansion vessel st No 22168 Transformator 220V 24V st No 24477 Gas valve SIT st No 40997 Grundfos pump st No 41367 Siphon st No 21059 1 Conjugated fitting GRF 3 st No 26072 Safety valve st No 40302 16 T...

Страница 22: ...tor 220V 24V st No 24477 Mixer AGU3 645A109 st No 42197 Ventilator RG130 0800 3612 st No 42195 Safety thermostat st No 40035 Gas valve SIT st No 40997 Three way valve st No 21053 Grundfos pump st No 4...

Страница 23: ...71 90 100 80 177 O60 425 800 160 800 1 Recuperative water inlet G 3 4 external thread 2 Heating water outlet 3 Gas inlet G 1 2 external thread 4 Service water inlet G 1 2 external thread 5 Service wat...

Страница 24: ...either concentric or located in such small distance within 50cm that it is subject to the same meteorological conditions C43 Separate connection to the two pipes of a common shaft The outlet can be ei...

Страница 25: ...ompliant with the requirements specified in Section 10 of the Act No 185 2001 Coll and Section 6 of the Act No 477 2001 Coll The product package is normally disposed of in a scrap paper collecting cen...

Страница 26: ...o the EC notified body No 1015 THERM 17 KD THERM 17 KDZ THERM 17 KDZ 5 test certificate of type according to the EC Directive on appliances burning gaseous fuel 90 396 EEC No E 30 00571 07 as of Augus...

Отзывы: