background image

TM

Electric Tankless Water Heater - 

Installation Manual and User Guide

29

EN

7.  Warranty Conditions

Warranty

The rights under this manufacturer’s warranty shall apply in addition to the 

buyer’s statutory rights. This warranty shall in no way restrict the buyer’s 

statutory rights in particularly towards the seller.  

Entitlement

The claiming of rights under this warranty shall be subject to the submis-

sion of the respective proof of purchase.

Content

We shall guarantee as the manufacturer that this product is free of material 

and manufacturing errors. Material and manufacturing errors arising during 

the warranty period shall justify the rights under the warranty. This warranty 

shall not cover errors due to improper installation or incorrect usage, incor-

rect operating conditions or defective maintenance or repair work. 
Normal wear and tear such as lime scaling shall also be excluded under this 

warranty. The warranty will not be valid if the problem is caused by extreme 

values of drinking water (pH value not between 6.5 and 9.5 and/or Cl above 

150 mg/l and/or Fe above 0.2mg/l). 

Claims

The warranty shall be valid for 24 months. The warranty period shall com-

mence on the day on which the product is purchased. Warranty services 

provided shall neither prolong the warranty period nor initiate a new war-

ranty period.

Invalidity of 
warranty

Attempted repairs carried out by a customer or third party that are not au-

thorized by us shall invalidate the warranty. The same shall apply if parts 

are installed in the product or connected to the product that are not original 

parts from us.

Restriction

This warranty shall be restricted to rectification and subsequent delivery. 

This warranty shall not include compensation, withdrawal from the agree-

ment, reduction in price or any reimbursement for consequential loss due to 

defects.
The statutory provisions and delivery conditions of the national company or 

importers must be observed.

compact & comfort manual thermoflow -na -bare.indd   29

2020/3/24   17:17

Содержание Elex 10PEB

Страница 1: ...nstalla on Guide User Manual and Warranty Informa on TM Electrically Controlled Tankless Water Heater TM Elex 8 5PEB Elex 10PEB Elex 12PEB Elex 15FEB Elex 18FEB Elex 21FEB Elex 24FEB compact comfort m...

Страница 2: ...al and User Guide EN 0 Contents Contents 2 Safety Instructions 3 Mounting Instructions 7 Technical Specifications 20 User Manual 24 Maintenance 25 Troubleshooting 26 Warranty Conditions 29 compact com...

Страница 3: ...ified by CSA Failure to observe this instruction may expose you or others to danger Failure to observe this instruction may lead to damage to the device Indicates live parts Failure to observe this in...

Страница 4: ...supply circuits must be disconnected After service work is complete proceed as during the rst time appliance start up The connection diagram or wiring diagram is marked Located on inside of Front Encl...

Страница 5: ...s enfants ayant des capacit s physiques sensorielles ou mentales r duites ou manquant d exp rience et de connaissances moins d avoir t supervis es ou instruites concernant l utilisation de l appareil...

Страница 6: ...nted water heating system No changes may be made to the appliance If the supply cord is damaged it must be replaced by the manufacturer its ser vice agent or similarly qualified persons in order to av...

Страница 7: ...reference of the rating plate on device Please take reference of the following diagram to connect power supply with Elex 8 5 10 12 PEB GR GR L2 L1 ThermoflowTM Tankless Water Heater Circuit Beaker El...

Страница 8: ...x 8 5 10 PEB Heating element Over pressure cutoff Outlet Inlet Main control PCB TRIAC Thermal cutoff L1 L2 Circuit diagram for Elex 12PEB Heating element Over pressure cutoff Outlet Inlet Main control...

Страница 9: ...Installation Manual and User Guide 9 EN Circuit diagram for Elex 15FEB Circuit diagram for Elex 18 21 24 FEB Unpacking Check if the device has been damaged in any way compact comfort manual thermoflo...

Страница 10: ...ncil Adhesive tape Wire stripper Environment To prevent damage during transport this unit is supplied in robust packaging Please recycle the packaging where possible Disposal of the appliance Old appl...

Страница 11: ...rounded properly Make sure taps flow control device be install on the outlet of the appliance The appliance must be connected to a ground fault circuit interrupter Locate the installation location of...

Страница 12: ...Conexi n a la pared Connection to wall Conexi n a la pared Connection to wall conexi n a la pared 8mm 5 16 8mm 5 16 8mm 5 16 8mm 5 16 Mindestabstand zur Decke Minimum distance to the ceiling Distancia...

Страница 13: ...kless Water Heater Installation Manual and User Guide 13 EN Elex 8 5 10 12 PEB max 1 A5 A6 A7 1 6 L1 L2 A8 L1 L2 Push the button to reset the switch compact comfort manual thermoflow na bare indd 13 2...

Страница 14: ...Guide EN Elex 8 5 10 12 PEB A9 Two wrenches should be used to fix the tube to the inlet and outlet Filter mat must be installed to the inlet A10 3 2 Display plug 1 A11 inlet outlet filter mat gasket...

Страница 15: ...d water connection Minimum distance to the ground Minimum distance to the ceiling Connection to wall Connection to wall Input electric cable Screws washers and anchors 5 16 5 16 5 16 4 8 4 4 5 16 Rev0...

Страница 16: ...c Tankless Water Heater Installation Manual and User Guide EN Elex 15 18 21 24 FEB B5 B6 max 1 B7 B8 Inlet Connector Outlet Connector Gasket Gasket compact comfort manual thermoflow na bare indd 16 20...

Страница 17: ...allation Manual and User Guide 17 EN Elex 15 18 21 24 FEB B9 1 6 L1 L2 L1 L2 B10 Push the button to reset the switch L1L2 L1L2 3 4 B11 2 1 Dis pla y plu g B12 Inlet Outlet compact comfort manual therm...

Страница 18: ...button to reset the switch as indicated in A8 This appliance must be grounded properly The electrical connection should be made by a qualified electrician in accor dance with the relevant regulations...

Страница 19: ...a qualified electrician in accor dance with the relevant regulations IEC NEC etc See image B11 B12 1 Attach the support to the bottom housing 2 Insert the display plug 3 Install the top of the housin...

Страница 20: ...ivity of the water supply 3300 in 3300 in 3300 in Flow rate t 45 F 240V 1 2 GPM 1 5 GPM 1 8 GPM Flow rate t 65 F 240V 0 8 GPM 1 1 GPM 1 2 GPM Heating system Bare element Bare element Bare element Temp...

Страница 21: ...2 8 AWG Resistivity of the water supply 3300 in 3300 in Flow rate t 45 F 240V 2 3 GPM 2 7 GPM Flow rate t 65 F 240V 1 6 GPM 1 9 GPM Heating system Bare element Bare element Temperature range 95 140 F...

Страница 22: ...6 AWG Resistivity of the water supply 3300 in 3300 in Flow rate t 45 F 240V 3 1 GPM 3 6 GPM Flow rate t 65 F 240V 2 2 GPM 2 5 GPM Heating system Bare element Bare element Temperature range 95 140 F 9...

Страница 23: ...ture rise Hot Water Temp Cold Water Temp 10 20 30 40 50 60 70 80 90 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 Temperature Rise F Flow Rate GPM Maximum Temperature Rise vs Flow Ra...

Страница 24: ...e that the minimum flow switch on flow of a water pressure operated device is reached the pressure loss head loss of the device fittings shower head shower hose and piping should all be considered whe...

Страница 25: ...till have problem never try to repair the hot water device yourself please contact the nearest service specialist for help Care The enclosure can simply be cleaned with a damp cloth Do not use aggress...

Страница 26: ...t is not heating the outgoing water temperature is the same as the cold water supply The digital display DOES light up but no tem perature display Flow rate is too low water pressure is too low Your w...

Страница 27: ...If it s a new installation have your electrician double check the wiring Is possible that the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 2...

Страница 28: ...can compensate for this by increasing the setting on your water heater if you need want hotter water Thermal loss due to long pipe run As the hot water from the heater runs through the hot water deli...

Страница 29: ...warranty The warranty will not be valid if the problem is caused by extreme values of drinking water pH value not between 6 5 and 9 5 and or Cl above 150 mg l and or Fe above 0 2mg l Claims The warran...

Страница 30: ...compact comfort manual thermoflow na bare indd 30 2020 3 24 17 17...

Страница 31: ...compact comfort manual thermoflow na bare indd 31 2020 3 24 17 17...

Страница 32: ...TM CFT_CPT NA B Rev 3 5 202003 Elex 8 5 10 12 PEB Elex 15 18 21 24 FEB compact comfort manual thermoflow na bare indd 32 2020 3 24 17 17...

Отзывы: