TM
Electric Tankless Water Heater -
Installation Manual and User Guide
19
EN
See image B3, B4
1. Use two pieces of tape to fix the template on the wall where the device is to be in-
stalled.
2. Drill four 8mm holes through the template, as indicated in
B3
.
3. Install cold water inlet connector and gasket to cold water supply (in the wall) on the
right, and hot water outlet connector to hot water supply (in the wall) on the left, as
shown in
B4
. Teflon tape can be used for sealing the threads. Make sure the arrow
on the inlet connector outward from the wall.
See image B5, B6, B7, B8, B9, B10
1. Insert the anchors into the holes drilled at last step.
2. Install the appliance with the supplied screws and spacers.
3. Install the hot water pipe to the left, and install the cold-water supply to the right, as
indicated in
B8
. Make sure the connections are watertight! To prepare the connec-
tion to the water supply, Teflon tape can be used for sealing the threads.
4. Cut the cable to the required length and connect it to the terminal block, press the
button to reset the switch, as
B9
and
B10
shown.
This appliance must be grounded properly!
The electrical connection should be made by a qualified electrician, in accor-
dance with the relevant regulations (IEC, NEC, etc.)
See image B11, B12
1. Attach the support to the bottom housing.
2. Insert the display plug.
3. Install the top of the housing.
4. Install the screw at the bottom.
5. Switch on the earth leakage circuit breaker, turn on the appliance and open the hot
water tap, wait for about 20 secs before the appliance start working.
Make sure only fittings for close-outlet water heaters can be used!
Make sure taps/flow control device be install on the outlet of the appliance!
Make sure inlet connector are installed as indicated in B4.
Commissioning
• Fill the device and vent it by opening a hot water tap connected to it.
• Only switch on the electrical supply once the device is clear of any air.
• Check the operation of the device.
Frost
The appliance is not to be installed in locations where freezing can occur.
The device should be installed in a vertical position in a room protected from frost and
in the proximity of the water connections.
In case the room cannot be protected against frost, the device should not be installed in
this room. Should the device be installed in such a room, the device should be emptied
before the frost danger will occur.
Do not switch on if there is a possibility that the water in the device is frozen.
compact & comfort manual thermoflow -na -bare.indd 19
2020/3/24 17:17