background image

SpeedVac™ SPD130DLX

 Introduction  |   1

Introduction

Thermo Scientific Savant SpeedVac™ SPD130DLX vacuum 
concentrator offers fast, reliable processing of samples. It 
effectively removes a broad range of aggressive and volatile 
solvents to concentrate or dry solutes, analytes and residues 
while providing complete sample recovery. 

The combination of vacuum, applied to the sample chamber 
from an external source, and centrifugal action promotes 
solvent evaporation without sample loss due to foaming or 
bumping. The evaporation process is accelerated with the 
addition of chamber heat to counteract the extreme 
evaporative cooling of the samples. The concentration 
process is completed with the addition of a vapor 
condensation trap available separately for virtually 100% 
solvent recovery. This results in a thorough evaporation 
process in a safe environment for both the sample and the 
user. The unit features an advanced front panel with dual 
timer for automatic or manual control of run conditions, it also 
features preset and user defined programs which enable user 
to retrieve and store application protocols for future use.

The compact, industrial strength SPD130DLX features:

Ultimate chemical resistance to aggressive solvents with 
the following provisions:

-

Components made of Teflon

®

 and Teflon

®

 coated 

materials used exclusively in the vapor path.

-

Dual valve manifold positioned to reduce solvent 
vapor exposure.

-

Dedicated bleed port added to assure unidirectional 
vapor flow and to purge bearings with fresh air.

Faster evaporation rate with the following enhancements:

-

Glass cover with lamps apply radiant heat to 
samples.

Microprocessor control of run and heat times offer fully 
unattended, automatic operation.

Built-in digital vacuum gauge allows continuous 
monitoring of process.

Vacuum based run terminates run when pre-set vacuum 
level is reached.

3 preset programs pre-loaded with default application-
based run parameters.

3 user-defined programs for custom application-based 
run parameters that enables user to retrieve and store 
protocols for future use.

Содержание SpeedVac SPD130DLX

Страница 1: ...Installation and Operation 80302133 Revision A July 2018 SpeedVac SPD130DLX Vacuum Concentrator...

Страница 2: ...mo Fisher Scientific Inc provides this document to its customers with a product purchase to use in the product operation This document is copyright protected and any reproduction of the whole or any p...

Страница 3: ...4 Installation of SPD130DLX 4 Operation 5 Description Of Control Panel 5 Manual Run 7 Auto Run Time 8 Auto Run Vacuum 8 Drying Rate 8 Preset Program Settings 9 Exporting Live Run Data 9 HyperTerminal...

Страница 4: ...th dual timer for automatic or manual control of run conditions it also features preset and user defined programs which enable user to retrieve and store application protocols for future use The compa...

Страница 5: ...dicates extreme low temperatures and high risk of frostbite Do not touch bare metal or samples with unprotected body parts This symbol indicates possible pinch points which may cause personal injury T...

Страница 6: ...tive Power 115 VAC 60 Hz 6 amps 230 VAC 50 Hz 3 amps Vacuum Chamber TEFLON coated chemical resistant aluminum casting Cover Heated cover with radiant lamps includes a safety interlock Induction Motor...

Страница 7: ...130DLX units configured for 230 VAC 50 Hz should be plugged into a circuit rated for at least 3 amps Note Do not use any detachable power cord that is not adequately rated for the unit Installation of...

Страница 8: ...hand to ensure alignment of the pin with the groove Secure the assembly by screwing the retaining knob into the drive shaft above the rotor Tighten it firmly but not excessively Description Of Contro...

Страница 9: ...meters is shown by the corresponding indicator that is illuminated 8 Minus Decrements the value of the selected parameter 9 Plus Increments the value of the selected parameter 10 View During a run pre...

Страница 10: ...tor with the supplied knob hand tight Close cover 10 Pre heat may be selected at this time to apply a 45 C heat to the chamber 11 Press the Manual Run button The cover locks and the lid locker indicat...

Страница 11: ...and remove samples Auto Run Vacuum 1 Refer to the Manual Run section for start up 2 To execute an Automatic Vacuum run execute the following steps a Select the Run Type as Vac b Use the Select button...

Страница 12: ...C The heat time is expressed as a 3 digit integer in minutes or CCC for continuous heating The runtime is expressed as a 3 digit integer in minutes The vacuum pressure is represented as a floating poi...

Страница 13: ...id stay mechanism that will assist the user in opening and closing the cover of the unit It will secure the lid and maintain it open allowing the user to operate the unit with both hands Figure 3 Lid...

Страница 14: ...cid Ammonium hydroxide n butyl alcohol Chloroform Cyclohexane DCM Ethyl acetate Ethanol Ethyl ether n Hexane n Heptane Isopropyl alcohol Isobutyl alcohol Methanol Petroleum ether n propyl alcohol Pyri...

Страница 15: ...0mm RH32 13 15 8 17 5 X 102 mm 15ml Corex tubes RH8 17 5 10 8 18 X 100 mm 17 x 95 16 x 100 RH8 18 CENTRIFUGE TUBES 12 10 15ml conical 16 x 120 mm RH10 15 40 6 50ml conical 28 x 115 mm RH6 50 FLASKS 80...

Страница 16: ...neutralizing solution for Oligo Preps Used on UVS850DDA only SCT120 Chemical trap order cartridges separately DTK120R Chemical trap kit for radioactivity compatible with all Thermo vacuum concentrator...

Страница 17: ...Pump ANT100 Exhaust recovery Post trap Vacuum Tubing From Cold Trap to Back of SPD130DLX UVS850DDA Vacuum Tubing From Back of SPD130DLX To Cold Trap SpeedVac Concentrator SPD130DLX Vacuum Tubing RVT45...

Страница 18: ...MA number issued by Thermo Costs of shipping the unit are not covered under warranty The warranty obliges you to follow the precautions in this manual When returning apparatus that may contain hazardo...

Страница 19: ...riciclato tramite queste medesime Ulteriori informazioni sulla conformit di Thermo Fisher Scientific con queste Direttive l elenco delle ditte di riciclaggio nel Vostro paese e informazioni sui prodo...

Страница 20: ...30 France 33 2 2803 2180 33 2 2803 2180 Germany 0800 1 536 376 49 6184 90 6000 0800 1 536 376 Italy 32 02 95059 552 39 02 95059 552 432 254 375 Netherlands 31 76 579 55 55 31 76 571 4440 Nordic Baltic...

Отзывы: