background image

In

 

the

 

United

 

States

:

For

 

customer

 

service

call 1

-

800

-

766

-

7000

To

 

fax

 

an

 

order

use 1

-

800-926

-

1166

To order online: thermofisher.com

Find

 

out

 

more

 

at

 

thermofisher.com

In

 

Canada

:

For

 

customer

 

service

call

 

1

-

800

-

234

-

7437

To

 

fax

 

an

 

order

use

 

1

-

800

-

463

-

2996

To order online: thermofisher.ca

For

 

Research

 

Use

 

Only.  Not

 

for

 

use

 

in

 

diagnostic

 

procedures. 

©

2020  Thermo  Fisher  Scientific  Inc.  All  rights

reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.

MaxQ 2000 CO2 Plus

Digital CO2 Resistant Shaker

Catalog #88881101B, #88881102B

               #88881103B, #88881104B

Operation Manual 0000847

Visit us online to register your warranty

www.thermoscientific.com/labwarranty

User Manual

Содержание MaxQ 2000 CO2 Plus

Страница 1: ...r online thermofisher ca For Research Use Only Not for use in diagnostic procedures 2020 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific an...

Страница 2: ...xtended Warranty for your Thermo Scientific products Whatever Thermo Scientific products you need or use we will be happy to discuss your applications If you are experiencing technical problems workin...

Страница 3: ...al Cable Output current of Control Box Maximum Shaking Speed Section 3 Operation Operations on the Control Panel Speed and Time Settings Alarm System Section 4 Application Section 5 Safety Tips Sectio...

Страница 4: ...xQ 2000 CO2 Plus Promotion Package for EMEA APAC includes CO2 resistant shaker 88881102B Universal Platform Flask Clamp Starter Kit Main Body Control Box General Power Adaptor US Plug CN Plug EU Plug...

Страница 5: ...recessed countersink head screws 2 18inch aluminum platform 3 Main body of CO2 resistant shaker 3 Section 1 Unpacking and Installation 1 2 Universal Aluminum Platform Installation 1 4 Rubber Mat Plat...

Страница 6: ...00 m Humidity 20 to 99 non condensing 2 2 Environmental Conditions Rotation Speed Load Timer Dimensions Weight Power Supply Others 5 Section 2 Overview 2 3 Safety Tips 1 Unplug and unload before movin...

Страница 7: ...1000ml 1000ml 250 2000ml 2000ml 200 3000ml 3000ml 200 5000ml 5000ml 150 Flask size Size Liquid volume Max Speed rpm 50ml 50ml 600 600 600 600 600 580 550 500 470 430 450 400 450 400 100ml 100ml 150ml...

Страница 8: ...has been designed with a soft start slow down providing a smooth acceleration deceleration during operation This feature will decrease splashing of solutions from vessels during operation Warning The...

Страница 9: ...operation the alarm will sound after 10 seconds if the unit has not begun shaking In addition the alarm will sound and stop for the speed over 650 rpm after 2 seconds 2 Once the shaker begins to alarm...

Страница 10: ...e power cord 2 Remove the platform with 4 screws 3 Remove top plate with 7 screws 4 Use 70 ETOH to clean the inner area 5 All allow the unit to dry for one hour reassemble unit and operate normally Se...

Страница 11: ...6mm 1 88881122B 18inch Aluminum platform N A 360x305x10 88881123 Rubber Mat platform 10 130x90x15 88881124 96 well microplate holder Table 6 2 18inch Aluminum Platform Description 50ml clamp 100ml cla...

Страница 12: ...Accessories Section 7 Troubleshooting To troubleshoot the unit refer to the table below If your problem persists contact your local sales service representative Indicator off No reaction No rotating...

Страница 13: ...the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non conforming parts must be returned to Thermo...

Отзывы: