The ELEX
euro
convective panel heater must not be installed
immediately below a wall socket. The heater must be connected
to a socket outlet or permanent terminal box at least 10cm to one
side of the heater. If the heater is installed in the Bathroom or in
humid area, the socket outlet or permanent terminal box must
conform to the IP24 requirement.
The ELEX
euro
convective panel heater must not be installed in a
draught likely to affect the control settings (under a ventilating fan, etc.)
4.2 Wall Mounting Bracket
The wall mounting bracket is oriented centrally (See RHS diagram).
Step 1
: Loosen the locking plate screw and rotate the locking plate
out of the fixing slot (See RHS images).
Then remove the mounting bracket from the heater.
Step 2
: Use the wall-mounting bracket as a template for marking
the fixing holes. Position the mounting bracket in the correct
position on the wall and mark the screw-holes through the 4
mounting holes (See RHS diagram).
Step 3
: Install the 4 fixing devices in the wall, ensuring they are
more than adequate to safely fix the heater to the wall.
(ST4 expansion screws are suggested).
Step 4
: Fix the bracket firmly to the wall using all 4 mounting locations.
Step 5
: Mount the heater on the bracket so the bracket protrusions
fix into the 4 slots on the back of the heater. (See RHS diagram).
Rotate the locking plate into the fixing slot and tighten the screw
To remove the heater, reverse the above operation.