1.4
Ordering
The table below describes ordering information for a standard DCT7088 flowmeter as well as available
options.
MODEL NUMBER
Series: Digital Correlation Transit Time Flowmeters
DCT7088
= DCT7088, RS232 digital interface with UltraScan signal analysis and configuration program
Battery Duration
1
=
8 hours
1
2
=
16 hours
Transducer Cable Length
16A
=
16 ft (5 m)
1
XXXXA
= increments of 10 ft (3 m) up to 1000 ft (305 m)
Additional Options
0704/0188
=
Ultrasonic Thickness Gauge (UTG), English units
0704/0187
=
UTG, metric units
22334-0001
=
Thermal printer kit
Typical Model Number: DCT7088-1-B-16A
1
standard
T
ABLE
1: O
RDERING
I
NFORMATION
1.5
Technical Specifications
1.5.1 Performance
Flow Range
0 to 40 ft/s (0 to 12 m/s)
Accuracy
±0.5% of velocity or ±0.05 ft/s (±0.0152 m/s), typical, digital output
Sensitivity
0.001 ft/s (0.3 mm/s) at any flow rate, including zero
Linearity
±0.1% of scale, digital output
Pipe Size
1 to 200 in (25 mm to 5 m)
Fluid
Homogeneous liquids without gas bubbles