8
Switch on the circuit breaker to turn on the heater.
Then turn the thermostat to the farthest clockwise position. The fan should start and the unit
begins heating the room,
and lamp is light.
After the room reaches comfort level, turn the
thermostat counterclockwise until the heater shuts off. The heater will automatically cycle around
this preset temperature. To increase the temperature, turn the thermostat knob clockwise. To
lower the temperature, turn the thermostat counterclockwise.
Press the switch to High or Low position for heat selection.
HIGH : 5000W
LOW : 2500W
Select a thermostat setting.
Ambient temperature is regulated by adjusting the thermostat to a desired position. Allow the unit to
operate and warm up the room. When the desired temperature is reached, turn the control knob
counterclockwise until the heater turns off. This is your ideal setting. The heater will start automatically
when the room temperature drops below this set point, and will turn off when the set point is reached.
To turn off the heater, switch off the circuit breaker.
The circuit breaker serves as
the power disconnection means.
This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If
the alarm flashes, immediately turn the heater OFF and inspect for any objects, on or adjacent to
the heater that may cause high temperatures. DO NOT OPERATE THE HEATER WITH THE
ALARM FLASHING. To reset the heater, switch the circuit breaker OFF, and wait five to ten
minutes for the unit to cool down before turning the heater on.
There is no user maintenance part except regular cleaning as following description. All other
servicing or maintenance should be performed by qualified service personnel.
Before any cleaning, make sure that:
1. Disconnect power supply at source.
Switch off the circuit breaker.
2. Wait for 60 minutes to ensure the heating element has cool down, and your heater is now ready
for cleaning.
Regular Cleaning:
1. Do not use cleaning liquid or other chemicals to spray on the unit.
2. Interior dust can often be removed by using a vacuum cleaner with a crevice tool attachment.
3. To clean enclosure, use a clean, soft and lightly damp cloth to gently wipe off the dirt from the
surface of the unit. Be sure not to wet the heating element and the switches. Allow the unit to dry
completely before using it.
CAUTION: DO NOT ALLOW WATER TO RUN INTO THE INTERIOR OF THE HEATER AS THIS
COULD CREATE A FIRE OR ELECTRIC SHOCK HAZARD, DAMAGING THE UNIT.
MAINTENANCE AND CLEANING