background image

 

IMPORTANT INSTRUCTIONS 

PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS HEATER 

 

NOTE: There may be a trace of smoke or odor when unit is first operated.  Don’t be alarmed. 
This indicates that a drop of oil fell on the heating coil during the manufacturing process. It 
will quickly evaporate and should not re-occur. 
Make sure that the room in which the appliance is located is well ventilated during this 
operation. It is normal for the appliance to emit small cracking sounds when you turn it on for 
the first time. Do not be alarmed. 

 

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE 
FOLLOWED TO REDUCE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY TO PERSONS OR 
PROPERTY, INCLUDING THE FOLLOWING: 
  
1)  Read all instructions before using this heater.  
2)  This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep 
combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3’ 
(0.9 m) from the front of the heater and keep them away from the sides and rear.  
3)  Extreme caution is necessary when any heater is used by or near children or invalids and 
whenever the heater is left operating and unattended.  
4)  Always switch off the heater when not in use.  
5)  Do not operate any heater after the heater malfunctions, has been dropped or damaged in any 
manner. Disconnect power at service panel and have heater inspected by a reputable electrician 
before reusing.  
6)  Do not use outdoors.  
7)  To disconnect heater, turn off power to heater circuit at main disconnect panel. 
8)  Do not install less than 6 feet (1.8 m) high from the floor and closer than 1 foot (0.3 m) to any 
adjacent vertical surfaces or walls. Keep at least 4.5 inches (11.5 cm) from the back wall (with or 
without using the wall hanging mounting bracket). 
9) Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause 
an electric shock or fire, or damage the heater.  
10) To prevent a possible fire, do not block air intakes or exhaust in any manner.  
11) A heater has hot and arcing or sparking parts inside. To reduce the risk of fire, do not use it in 
areas where gasoline, paint, or flammable vapors and liquids are used or stored.  
12) Use this heater only as described in this manual. Any other use not recommended by the 
manufacturer may cause fire, electric shock, or injury to persons.  
13) This product must be installed by a certified electrician, in accordance with local codes.  
14) For supply cables, use 10 AWG (5.3 mm

2

) copper wires . 

15) This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If 
the alarm flashes, immediately turn the heater OFF and inspect for any objects, on or adjacent to the 
heater that may have blocked the airflow or otherwise cause high temperatures to have occurred.   
DO NOT OPERATE THE HEATER WITH THE ALARM FLASHING. To reset the heater, switch the 

CIRCUIT BREAKER

 OFF, and wait five to ten minutes for the unit to cool down before turning the 

heater on. 
16

This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction regarding use of the appliance by a person responsible for their 
safety.

   

Children should be supervised to ensure that they do not play with the appliance. 

 

CAUTION – High temperature, risk of fire, keep electrical cords, drapery, furnishings, and 
other combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side 
and rear. 

 

SAVE THESE INSTRUCTIONS 

Содержание PH-950N

Страница 1: ...uding birds are extremely sensitive to the fumes produced during the first time use of many appliances These fumes are not harmful to humans but we recommended that you do not use your heater around birds and small pets during its initial use until the manufacturing corrosion coatings burn off Technical support 1 866 206 0888 Service email info mecanair net ...

Страница 2: ...2 Important Instructions 3 Installing Instructions 4 5 Specifications and Wiring Diagram 6 Parts of the heater 7 Operating Instructions 7 Maintenance and Cleaning 8 Troubleshooting 9 TABLE OF CONTENTS ...

Страница 3: ... 5 inches 11 5 cm from the back wall with or without using the wall hanging mounting bracket 9 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 10 To prevent a possible fire do not block air intakes or exhaust in any manner 11 A heater has hot and arcing or sparking parts inside To reduce the risk of...

Страница 4: ...electrical cords drapery furnishings and other combustibles at least 3 feet 0 9 m from the front of the heater and away from the side and rear WARNING To reduce the risk of fire do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater INSTALLATION INSTRUCTION 1 Keep the unit at least 6 feet 1 8 m away from the floor This minimum distance must be maintained 2...

Страница 5: ...le in flexible conduit and connect to the wiring compartment via the knock out at back side of the unit 12 Make the connections properly with connectors which are suitable for the conductor size in cluding grounding wirings And after making the connections arrange the pigtail leads of unit and power supply wires in the wiring compartment 13 Replace the wiring compartment connection cover and lock ...

Страница 6: ...6 5000W Ceiling Wall Mounted Garage Heater Model PH 950N Volt 240 V Watts 5000 W Frequency 60 Hz Recommended Heating Capacity 1 25 watts ft 0 03m Wiring diagram SPECIFICATIONS 3 ...

Страница 7: ...A 70 A circuit breaker must be installed and serviced only by qualified electrical personnel Always use a properly rated voltage sensing device to confirm power is off The Select switch on the heater is only for function selection Use circuit breaker as power ON OFF device The circuit breaker is to be installed by certified electrican and shall be located in line of sight from the heater location ...

Страница 8: ...alarm to warn that parts of the heater are getting excessively hot If the alarm flashes immediately turn the heater OFF and inspect for any objects on or adjacent to the heater that may cause high temperatures DO NOT OPERATE THE HEATER WITH THE ALARM FLASHING To reset the heater switch the circuit breaker OFF and wait five to ten minutes for the unit to cool down before turning the heater on There...

Страница 9: ...erature adjust thermostat control knob to a higher setting Breaker Fuse has been tripped Check your electrical box to confirm the breaker has not been blown This may occur if the receptacle is shared between other high consumption appliances The heater is producing a burning smell Check ensure there are no combustible materials within 0 9 meters 3 feet surrounding the heater Remove any combustible...

Отзывы: