Thermo Scientific PowerEase PS0300 Скачать руководство пользователя страница 13

PowerEase

®

 300W Power Supply User Guide

  

 

13

 

 

17B

Explanation of symbols and warnings 

46B

Symbols and 

warnings 

Symbol 

English 

Français 

 

Caution, risk of electrical shock 

Attention, risque de choc électrique 

 

Caution, risk of danger 

Consult the manual for further 
safety information.

 

Attention, risque de danger 

Consulter le manuel pour d’autres 
renseignements de sécurité. 

 

 

Do not dispose of this product in 
unsorted municipal waste. 

 CAUTION! 

To minimize 

negative environmental impact 
from disposal of electronic waste, 
do not dispose of electronic waste 
in unsorted municipal waste. 
Follow local municipal waste 
ordinances for proper disposal 
provision and contact customer 
service for information about 
responsible disposal options. 

Ne pas éliminer ce produit avec les 
déchets usuels non soumis au tri 
sélectif. 

CAUTION! 

Pour minimiser 

les consequences négatives sur 
l’environnement à la suite de 
l’élimination de déchets 
électroniques, ne pas éliminer ce 
déchet électronique avec les 
déchets usuels non soumis au tri 
sélectif. Se conformer aux 
ordonnances locales sur les 
déchets municipaux pour les 
dispositions d’élimination et 
communiquer avec le service à la 
clientèle pour des renseignements 
sur 

les options d’élimination 

responsable. 

 

Indicates conformity with European 
Union requirements for safety and 
electromagnetic compatibility. 

Indique la conformité avec les 
prescriptions en matière de sécurité 
et de compatibilité électromagnétique 
de l'Union européenne.  

 

Indicates conformity with Australian 
standards for electromagnetic 
compatibility. 

Indique la conformité avec les 
normes australiennes de 
compatibilité électromagnétique. 

 

Indicates conformity with safety 
requirements for Canada and USA. 

Indique la conformité avec les 
prescriptions en matière de sécurité 
du Canada et des États-Unis. 

 

Содержание PowerEase PS0300

Страница 1: ...PowerEase 300W Power Supply Catalog Numbers PS0300 PS0301 PS0302 Publication Number MAN0008988 Revision D 0 Research Use Only Not for use in diagnostic procedures...

Страница 2: ...SE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT TO THE EXTENT ALLOWED BY LAW IN NO EVENT SHALL LIFE TECHNOLOGIES AND OR ITS AFFILIATE S BE LIABLE WHETHER IN CONTRACT TORT WA...

Страница 3: ...peration modes 7 15BLimiting parameter settings 11 2BAppendix A 12 16BGeneral safety 12 Instrument safety 12 17BExplanation of symbols and warnings 13 1Product regulatory compliance 13 3BAppendix B 15...

Страница 4: ...ims must be filed with the carrier keep the supplied box for inspection The warranty does not cover in transit damage To ensure safe reliable operation always operate the PowerEase 300W Power Supply i...

Страница 5: ...wer Supply Constant Voltage Power or Current Capable of running multiple electrophoresis units LCD display with clear menu prompts for easy use Programming capabilities for limiting voltage V current...

Страница 6: ...e the cursor position down and decrease values when settings are flashing Mode Select Constant Mode or Program Mode The Mode key cycles between voltage current power and time settings allowing values...

Страница 7: ...riations in buffer conditions can result in exceeding the power supply s maximum voltage current or power output capacity and produce undesirable variations in performance 33BRecommendation The durati...

Страница 8: ...Mode the unit defaults to the Constant Voltage mode and Volts V displays on the left side of the screen in large characters The controlling value Volts V Amps A or Watts W is always displayed on the...

Страница 9: ...Power from the display screen The screen displays the selected operation mode on the left side of the display 5 Use the arrow keys to set the selected operation voltage VOLT current AMP or Power WAT t...

Страница 10: ...of the run press the Mode key 7 Voltage will appear on the display to enter voltage press Mode key 8 To change voltage use the arrow keys 9 Select AMP or WAT by pressing the Mode key until desired par...

Страница 11: ...ng margin of safety over time The same voltage setting can be used regardless of the number or thickness of gels being electrophoresed 42BCurrent limiting Discontinuous buffer systems and to a lesser...

Страница 12: ...indicator light at the Start Stop key is on or when RUNNING is displayed on the screen 2 WAIT at least 5 seconds after stopping a run before handling output leads or connected apparatus 3 ALWAYS make...

Страница 13: ...tri s lectif CAUTION Pour minimiser les consequences n gatives sur l environnement la suite de l limination de d chets lectroniques ne pas liminer ce d chet lectronique avec les d chets usuels non so...

Страница 14: ...uency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely...

Страница 15: ...cell Correct the condition by making sure the tape is removed from the pre cast gel buffers are prepared correctly and the recommended volume of buffer is added to the electrophoresis unit Operation s...

Страница 16: ...oved during a run Buffer leaking in a connected system Excessive temperature increase Excessive buffer evaporation Loose connection in a connected system Current set too low Change in constant mode Vo...

Страница 17: ...ghly conductive chloride ions in the gel are gradually replaced by the slower moving less conductive glycine ions from the running buffer as the gel runs As a result the resistance of the gel increase...

Страница 18: ...ant Current Constant Power 1V step 10 mA step 1 watt step Crossover Automatic Display type Backlit LCD Graphic type Display size 53 64 x 15 64 mm W x H Pause function Yes Safety features No Load Detec...

Страница 19: ...Appendix F To replace the fuse 1 Turn off the main power switch at the rear of the PowerEase 300W Power Supply and detach the power cord from the rear of the PowerEase 300W Power Supply 2 Open the fu...

Страница 20: ...tomer training Download software updates and patches 57BSafety Data Sheets SDS Safety Data Sheets SDSs are available at HUwww lifetechnologies com supportUH 58BCertificate of Analysis The Certificate...

Отзывы: