background image

Section 4  Overview

4.1 Specifications

 Speed Range..................................................................1~70rpm
 Display Accuracy..................................................................1rpm
 Speed Accuracy.................

±

1rpm

50rpm, ±2rpm

50rpm

Rocking Mode..........................Left right reciprocating motion
Angle Range........................................................................1°~24°
Angle Accuracy...............………................................…………...……±1°

Maximum Load (Centered on tray)......................8kg@

±12°

                                                                                       @

40rpm

Timing Range…………………........0 (Continuous) / 1s - 9999 min

Overall Dimensions........................................390×292×206mm
Tray Dimensions...............................................322×282×19mm
Packaging Dimensions.................................487×387×354mm

Net Weight.............................................................11.5Kg(25.3lb)
Gross Weight.........................................................13.5Kg(29.8lb)

Input Requirement....................100-240VAC~, 50/60Hz, 0.1A
Output Requirement.................................................24V     , 2.5A

Certificate.................................RoHS, WEEE, cCSAus, CE Mark

Application Environmental Conditions: Indoor use
Temperature....................................................................5 to 40

Voltage Fluctuation.....................±10% of the nominal voltage
Altitude...........................................................................

2,000 m

Humidity...................................................................... 20% to 85%

                                                                

Storage Environmental Conditions
Temperature....................................................................0 to 60

Humidity.......................................20% to 90%, non-condensing

4.2 Environmental Conditions

4.3 Safety Instructions

Rotation Speed

Rocking Angle

Load

Time

Size

Weight

Power Supply

Others

Please read the entire instruction manual 
before operating the Digital Platform 
Rocker.

WARNING DO NOT

 use the Digital 

Platform Rocker in a hazardous 
atmosphere or with hazardous 
materials for which the unit was not 
designed. Also, the user should be 
aware that the protection provided by 
the equipment may be impaired if 
accessories used are no provided or 
recommended by the  manufacturer, 
or are used in a manner not specified 
by the manufacturer.

CAUTION !

 To avoid electrical shock, 

completely cut off power to the unit 
by disconnecting the power cord 
from the unit or unplug from the wall 
outlet. Disconnect unit from the 
power supply prior to maintenance 
and service. Any spills should be 
removed promptly. Bio hazard spills 
should be cleaned using approved 
liquid promptly. Solvent spills are a 
fire hazard.
Stop the unit immediately, and DO 
NOT operate until clean up is 
complete and vapors have 
dissipated.

DO NOT 

immerse the unit for 

cleaning.

DO NOT 

operate the unit if it shows 

signs of electrical or mechanical 
damage.

Position of Loads

Place the loads in the recommended 
positions below:
1.  Place load at the center of the tray.
2.  Place loads symmetrically around the 
    center of the tray.
3.  Make sure to use rubber strips to 
    fasten containers onto the tray.

Symmetrical placement

5      Section 4  |  Overview

Asymmetrical placement

Digital Platform Rocker      6

Содержание 88882013

Страница 1: ...fisher com Find out more at thermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca Operating Manual Revision A 04 01 2021 2021 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified ...

Страница 2: ...rview Specifications Environmental Conditions Safety Instructions Loads Angle and Speed Section 5 Operation Control Panel Installation of Two Trays Installation Settings Section 6 Safety Tips and Maintenance Section 7 Troubleshooting Section 8 Optional Accessories Section 9 Warranty Information Section 10 Compliance 16 Contents 1 2 2 2 3 3 4 4 5 5 5 6 7 8 8 9 10 10 12 13 14 15 ...

Страница 3: ... power switch and for allowing the instrument to run without impediment Do not install the stirrer near machinery generating high frequency noise Avoid installation close to high frequency welding machine sewing machine or mass SCR controller Do not inject any liquid and inflammable things inside of product Do not pour water or put liquid on the top of the product when cleaning Disconnect the main...

Страница 4: ...ed during transit After unpacking check that all unit parts and accessories are as listed below Contact us or the agent from which you purchased the unit if any components were omitted 3 Section 3 Inspection and Installation Digital Platform Rocker 4 General Power Adaptor US Plug CN Plug EU Plug UK Plug Catalog Number 88882013 1 10 N A N A N A 6 1 1 88882014 10 1 N A 6 1 1 1 1 Figure Dimpled Rubbe...

Страница 5: ...orm Rocker in a hazardous atmosphere or with hazardous materials for which the unit was not designed Also the user should be aware that the protection provided by the equipment may be impaired if accessories used are no provided or recommended by the manufacturer or are used in a manner not specified by the manufacturer CAUTION To avoid electrical shock completely cut off power to the unit by disc...

Страница 6: ...r stop the instrument Run indicator The light is on when the instrument is running and off when the instrument is in standby Mode button Switch modes between Speed and Tilt settings Tilt indicator The light is on when the instrument is in Tilt Adjustment Mode Speed indicator The light is on when the instrument is in Speed Adjustment Mode Gear I When the switch is in gear 1 the instrument power is ...

Страница 7: ... Press the Time setting knob To decrease time rotate the knob counter clockwise to increase time rotate the knob clockwise then press the knob with in 5sec to confirm the setting the digital tube will stop flashing and the time setting is complete the instrument is in timer mode Speed Settings 1 Press the button and the Speed indicator light will be on 2 Press the Speed Tilt setting knob To decrea...

Страница 8: ...arning The operator is not permitted to gain access using a tool to a part which in normal use may be hazardous live Digital Platform Rocker 12 Run and Stop Press button and the instrument will start running with the specified settings and the Run indicator light will be on The Time dispaly window will show the cumulative time Continuous Mode or remaining time Timer Mode and the Speed Tilt display...

Страница 9: ...rews Place instrument at a flat and firm suface Fasten housing screws Other Keep record for maintenance Shut down and restart useless please contact Thermo Scientific Err1 Operational obstruction Section 8 Optional Accessories Description Cat No Max Qty Figure Rubber Mat DoubleLayerTrayw 6screws 88882102 88882103 88882101 88882148 1 1 6 Rubber Strips 6 Ea pack Dimpled Rubber Mat General Power Adap...

Страница 10: ...ice and special application Outside the USA please contact local Thermo Technical Services Department or local distributor for warranty information Section 10 Compliance 1 European Union The European voltage models of this product meet all the applicable requirements of the European Directives and therefore display the CE Marking These Directives are captured in the EU Declaration of Conformity wh...

Страница 11: ... the Control of Pollution Caused by Electronic Information Products ACPEIP A label of conformance such as one of the following may be found on the product 5 End of Life Care Some considerations and suggestions are listed below for proper disposal of this product While addressing these actions for safe recycling and disposal please follow all guidelines Safety Data Sheets SDS or regulations applica...