All installations and services must be performed by qualified service personnel.
1
I.
FURNACE SPECIFICATIONS (SHIPPED SETTINGS)
OL SERIES
MODEL NO.
OL2-56
OL5-85
OL11-105
HEAT INPUT RATE IN BTU/HR
70,000
106,250
126,000
HEATING CAPACITY IN BTU/HR
56,000
85,000
101,000
HEIGHT OF CASING
34-3/4”
43-1/4”
46-1/2”
WIDTH OF CASING
19”
25”
25”
DEPTH OF CASING
48”
50-1/4”
54-1/2”
WARM AIR OUTLET
17 x 17
20 x 20
20 x 20
RETURN AIR INLET
17 x 17
20 x 14
20 x 16
DIA. OF FLUE OUTLET
5”
6”
6”
FLOOR-CENTER OF FLUE
29-1/4”
36”
38-1/2”
FLOWRATE from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE
COOLING
COOLING
COOLING
@2 TON SWITCH SELECTION (CFM)
800
800
800
@2-1/2 TON SWITCH SELECTION (CFM)
1000
1000
1000
@3 SWITCH SELECTION (CFM)
1200
1200
1200
@3-1/2 TON SWITCH SELECTION (CFM)
1400
1400
1400
HEATING
HEATING
HEATING
@70deg SWITCH SELECTION (CFM)
737
1134
1335
APPROX TEMPERATURE RISE (°F)
70
70
70
BLOWER MOTOR HP
1/2
1/2
1/2
NOZZLE SIZE
.55
.75
.90
NOZZLE SPRAY ANGLE PATTERN
80º Hollow
80º Hollow
80º Hollow
LARGEST RECOMMENDED
AIR CONDITIONER
3.5 Ton
3.5 Ton
3.5 Ton
SIZE OF FILTERS
16” x 20”
20” x 20”
20” x 25”
NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is
required.
4.
Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps, for all models).
5.
All specifications are subject to change without notice.