Unit Operation
47
CAUTION: If the unit is in CYCLE-SENTRY null and the
mode is switched to Continuous Mode, the unit will start
automatically.
Selecting the High Speed
Lock-Out Feature
If the High Speed Lock-Out feature is enabled and turned on,
the unit will run only in low speed until the High Speed
Lock-Out feature is turned off or the High Speed Lockout
Timer is exceeded. This feature is typically used in noise
sensitive areas to reduce unit engine noise.
High Speed Lock-Out is turned on or off by pressing the HIGH
SPEED LOCKOUT Key when the unit is turned on. Pressing
this key will turn High Speed Lock-Out on, pressing it again
will turn High Speed Lockout off. If High Speed Lockout is
turned on, unit will switch to low speed operation and the
amber LED indicator will glow. No further high speed
operation is allowed until this feature is turned off or the High
Speed Lockout Timer is exceeded.
IMPORTANT: HIGH SPEED LOCKOUT TIMER: If High
Speed Lockout Mode is selected, the High Speed Inhibit
Timeout feature may be enabled to return the unit to normal
operation after a set time period has expired. This prevents
unintended extended operation with high speed operation
locked out. The time period may be set from 15 minutes to 2
hours. If a time period is set and exceeded, the unit will
return to normal operation with high speed operation allowed
and the amber LED indicator will turn off. If necessary to
return to High Speed Lockout Mode, press the HIGH
SPEED LOCKOUT Key again.
The unit shown in Figure 33 has High Speed Lockout turned
on.
.
Figure 33: HIGH SPEED LOCKOUT Key