50
Installing the Remote Power Receptacle (OPTION)
Choose an appropriate location to mount the power receptacle that
provides for safe and easy access for connecting the power cord.
North American Units (Detail A)
1. Measure and drill three 13 mm (.500 in.) holes into truck body.
2. Insert the supplied rubber blind nuts into each hole in truck body.
3. Install the receptacle to the truck box with the supplied 1/4 x 20
mounting hardware and tighten securely.
4. Route and secure the harness with supplied clamps and screws.
International Units (Detail B)
1. Measure and drill four 9.5 mm (.375 in.) holes into truck body
2. Insert the supplied rubber blind nuts into each hole in truck body.
3. Install the receptacle to the truck box with the supplied 10-32 mounting
hardware and tighten securely.
4. Route and secure the harness with supplied clamps and screws.
DANGER: To prevent serious injury or death, the electric standby
power cord must not be connected to the unit during installation!
Содержание T-1000M
Страница 2: ......
Страница 5: ...3 Installation Manual for T Series Systems ...
Страница 12: ...10 Service Area T 580R T 600R T 680R T 680R T 680S T 800M T 800R T 880R T 880S ...
Страница 13: ...11 Service Area T 1000M T 1000R T 1080R T 1080S and T 1200R ...
Страница 14: ...12 Remote Power Receptacle Dimensions OPTION NORTH AMERICAN MODELS INTERNATIONAL MODELS ...
Страница 15: ...13 Battery Box Dimensions OPTION ...
Страница 16: ...14 Remote Status Light Dimensions OPTION ...
Страница 17: ...15 HMI Controller Dimensions HMI Controller LED Display HMI Controller Graphics Display ...
Страница 25: ...23 Required Tools ...
Страница 27: ...25 Installation Components ...
Страница 29: ...27 Uncrating the Unit ...
Страница 31: ...29 Installing the Unit ...
Страница 33: ...31 Installing the Hose Management Caps Cutout Guide Marks Front of Unit ...
Страница 35: ...33 Installing the Hose Management System OPTION Front of Unit ...
Страница 39: ...37 Securing the Evaporator Drain Hoses ...
Страница 41: ...39 Installing the Fuel Pickup Tube Into a Steel or Aluminum Tank ...
Страница 43: ...41 Installing the Fuel Pickup Tube Into a Plastic Tank ...
Страница 45: ...43 Installing the Steel Fuel Tank 1 2 3 4 ...
Страница 47: ...45 Installing the Aluminum Fuel Tank OPTION 1 2 3 4 ...
Страница 49: ...47 Installing the Fuel Pump and Fuel Lines ...
Страница 51: ...49 Installing the ServiceWatch Remote Download Port ...
Страница 53: ...51 Installing the Remote Power Receptacle OPTION ...
Страница 55: ...53 Installing the Remote Status Light OPTION ...
Страница 57: ...55 Installing the HMI Controller NOTE HMI with LED Display shown HMI with Graphics Display installs the same ...
Страница 59: ...57 Installing the Battery Box OPTION ...
Страница 61: ...59 Battery Connections ...
Страница 63: ...61 Installing the Door Switch OPTION Right Angle Mounting Top x Top Mounting Side x Side Mounting ...
Страница 69: ...67 ...
Страница 70: ......