![Thermo King SLXi-300 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/thermo-king/slxi-300/slxi-300_maintenance-manual_1104354019.webp)
TK 61552-2-MM-EN
19
Table 1.
(continued)
Drive
Model 30
Direct to compressor; belts to fans, alternator, and water
pump
Model 50
Centrifugal clutch to compressor; belts to electric standby
motor, fans, and water pump
Belt Tension
Table 2.
Use of Frequency Gauge P/N 204-1903 to measure
frequency (Hz) is recommended.
Model 30/50
New Belt
Field Reset
Electric Motor/Compressor Drive
Belt
Units fitted with original SLX clutch (up until build
date 13 August 2013)
73-76
67-72
Units fitted with SLX clutch retrofit (P/N 78-1884)
Use service tool P/N 204-2436 to set belt tension.
Distance of 139.0 mm as set by service tool equates
to 78-81 Hz for a new belt, and 69-73 Hz for a field
reset belt.
Units fitted with SLXe/SLXi clutch (P/N 77-3189)
Use service tool P/N 204-2436 to set belt tension.
Distance of 139.0 mm as set by service tool equates
to 95 Hz for a new belt.
Fan Drive Belt
SLX/SLXe/SLXi
106-118
95-106
Water Pump Belt
Tension Number on TK Gauge 204–427 Field Reset: 35-40
Refrigeration System
Table 3.
Compressor
Thermo King X430P
®
Refrigerant Charge - Type
SLXi-300, SLXi-300 Whisper Pro
SLXi-400
C
CA
AU
UT
TIIO
ON
N
H
Ha
azza
arrd
do
ou
uss!!
F
Fllu
uo
orriin
na
atte
ed
d R
Re
effrriig
ge
erra
an
ntt g
ga
asse
ess ssh
ho
ou
ulld
d n
no
ott b
be
e
v
ve
en
nttiilla
atte
ed
d tto
o tth
he
e a
attm
mo
ossp
ph
he
erre
e..
5.00 kg - R404A/R452A*
5.70 kg - R404A/R452A*
Compressor Oil Charge
X430LSC5
4.10 liters/litres**
6.62 liters/litres (deep sump)**
Compressor Oil Type
Polyol Ester type P/N 203-413
High Pressure Cutout
Opens: 32.41 +/- 0.48 bar (470 +/-7
psi)
Closes: Automatic reset @ 25.86 +/-
2.62 bar (375 +/- 38 psi)
High Pressure Relief
Valve
Opens: 34.48 +/- 3.45 bar (500 +/- 50
psi)
Reset: 27.58 bar (400 psi)
Heat/Defrost Method
Engine Operation
Electric Operation
Hot gas
Hot gas and electric heater strips (Model
50)