Installation
1. Place the evaporator coil assembly in position and install the mounting bolts.
2. Solder the hot gas line and suction line connections to the evaporator coil.
3. Solder the distributor to the expansion valve assembly.
4. Reinstall the heat exchanger mounting hardware.
5. Reinstall the sensors.
6. Replace Drier
7. Pressurize the low side and test for leaks. If no leaks are found, evacuate the low side.
8. Clean the suction line to a bright polished condition. Install the feeler bulb on the side of the
suction line in its former position. The feeler bulb must make good contact with the suction
line or its operation will be faulty. Wrap with insulating tape.
9. Pressurize the low side and test for leaks. If no leaks are found, evacuate the low side.
10. Install the high temperature cutout switch and electric heaters (Model 50 units)
11. Reinstall the evaporator access panels.
12. Back seat the receiver tank outlet valve and place the unit in operation. Check the refrigerant
charge and the compressor oil. Add as required.
Accumulator
Removal
1.
Pump down the low side and equalize the pressure to slightly positive.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
U
Usse
e a
a h
he
ea
att ssiin
nkk o
orr w
wrra
ap
p E
ET
TV
V w
wiitth
h w
we
ett rra
ag
gss tto
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
giin
ng
g tth
he
e E
ET
TV
V..
2.
Unsolder the inlet and outlet suction lines from the accumulator.
3.
Unbolt and remove the accumulator from the unit.
Installation
1.
Place the accumulator in the unit and tighten the mounting bolts and nuts.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
U
Usse
e a
a h
he
ea
att ssiin
nkk o
orr w
wrra
ap
p E
ET
TV
V w
wiitth
h w
we
ett rra
ag
gss tto
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
giin
ng
g tth
he
e E
ET
TV
V..
2.
Solder the inlet and outlet suction lines to the accumulator.
3.
Replace Drier
4.
Pressurize the low side and test for refrigerant leaks. If no leaks are found, evacuate the low
side.
5.
Open the refrigeration valves and place the unit in operation. Check the refrigerant charge
and the compressor oil. Add as required.
Three-Way Valve Repair
N
No
otte
e:: The three-way valve can be repaired in the unit if leakage or damage to the PTFE seals
should occur. There is usually enough give in the copper tubing to separate the three
sections of the valve without unsoldering any tubes.