Refrigeration Service Operations (Rev. 04/02)
68
2.
Install and tighten the bypass flare nut on the check
valve outlet. Hold the check valve with a back-up
wrench on the hex.
3.
Pressurize the low side and test for leaks. If no leaks are
found, evacuate the system.
4.
Open the bypass service valve and place the unit in
operation.
RECEIVER TANK
Removal
1.
Remove the refrigerant charge.
2.
Unsolder the condenser check valve line from the
receiver tank. Disconnect the filter drier inlet and the
bypass check valve lines. Remove the check valve from
the receiver tank.
3.
Unbolt the mounting brackets and remove the receiver
tank from the unit.
Installation
1.
Coat the bypass check valve fittings with compressor
oil. Install the check valve on the receiver tank outlet
tube. Tighten securely, holding the hex on the receiver
tank outlet tube with a back-up wrench.
2.
Place the receiver tank in the unit and install the mount-
ing bolts and nuts loosely. Position the receiver tank so
that the sight glass is clearly visible through the view-
ing hole in the mounting bracket.
3.
Solder the condenser check valve line to the receiver
tank.
4.
Connect the bypass check valve and filter drier inlet
lines.
5.
Tighten the receiver tank mounting hardware securely.
6.
Pressurize the refrigeration system and check for leaks.
If no leaks are found, evacuate the system.
7.
Recharge the unit with proper refrigerant.
FILTER DRIER
Removal
1.
Pump down the refrigeration system and equalize the
pressure to slightly positive.
2.
Disconnect the nuts at the ends of the drier.
3.
Loosen the mounting hardware and remove the drier.
Installation
1.
Place the new O-rings in the ORS fittings on the ends
of the drier.
2.
Install the new drier and tighten the mounting screws
and nuts.
3.
Install and tighten the inlet nut. Hold the drier with a
back-up wrench on the hex behind the inlet fitting.
4.
Release a small amount of refrigerant to purge the air
through the drier. Then tighten the outlet nut.
5.
Pressurize the system and inspect for leaks. If no leaks
are found, open the refrigeration valves and place the
unit in operation.
EXPANSION VALVE ASSEMBLY
Removal
1.
Pump down the low side and equalize the pressure to
slightly positive.
2.
Remove the evaporator access panels.
3.
Remove the feeler bulb from the clamp. Note the posi-
tion of the feeler bulb on the suction line.
4.
Disconnect the equalizer line from the suction line.
Содержание SB-III 30 SR+
Страница 4: ......
Страница 8: ......
Страница 10: ...ii ...
Страница 14: ...4 ...
Страница 24: ...Unit Description Rev 04 02 14 Unit Photos Front View AGA231 ...
Страница 25: ...Unit Description Rev 04 02 15 1 Defrost Damper 2 X430 Compressor 3 TK 486 Engine Back View AEA698 2 3 1 ...
Страница 28: ...18 ...
Страница 66: ...56 ...
Страница 98: ...88 ...
Страница 110: ...100 ...
Страница 111: ...101 Early Model Coiled Wire Fuse Link Wiring Schematic ...
Страница 112: ...102 Early Model Coiled Wire Fuse Link Wiring Diagram Page 1 of 4 ...
Страница 113: ...103 Early Model Coiled Wire Fuse Link Wiring Diagram Page 2 of 4 ...
Страница 114: ...104 Early Model Coiled Wire Fuse Link Wiring Diagram Page 3 of 4 ...
Страница 115: ...105 Early Model Coiled Wire Fuse Link Wiring Diagram Page 4 of 4 ...
Страница 116: ...106 Late Model Fuse Link in Battery Cable Wiring Schematic ...
Страница 117: ...107 Late Model Fuse Link in Battery Cable Wiring Diagram Page 1 of 4 ...
Страница 118: ...108 Late Model Fuse Link in Battery Cable Wiring Diagram Page 2 of 4 ...
Страница 119: ...109 Late Model Fuse Link in Battery Cable Wiring Diagram Page 3 of 4 ...
Страница 120: ...110 Late Model Fuse Link in Battery Cable Wiring Diagram Page 4 of 4 ...