67
Terminating a Defrost Cycle
The defrost cycle terminates automatically when the coil
temperature is greater than or equal to 58 F (14 C) or the
defrost timer expires. Defrost can also be terminated by turning
the unit off and back on.
NOTE: If Rail Alternate is set YES the defrost cycle
terminates at 70 F (21 C) or if the defrost timer expires.
Selecting Cycle Sentry or
Continuous Mode
When Cycle Sentry Mode is selected the unit will start and stop
automatically to maintain setpoint, keep the engine warm and
the battery charged. When Continuous Mode is selected, the
unit starts automatically and runs continuously to maintain
setpoint and provide constant airflow.
IMPORTANT: Cycle Sentry or Continuous Mode may not be
selectable if OptiSet Plus is in use.
See Figure 73 for an overview of the Selecting Cycle Sentry
or Continuous Mode procedure.
If the unit is operating in Cycle Sentry Mode, the Cycle Sentry
Icon will be present in the upper right corner of the display as
shown below. If the Cycle Sentry Icon (Figure 68) is not
present the unit is operating in Continuous Mode.
Figure 68: Cycle Sentry Icon
If allowed by OptiSet Plus, Cycle Sentry Mode or Continuous
Mode is selected by pressing the Cycle Sentry/Continuous Key
as shown in Figure 69.
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
Содержание Precedent C-600
Страница 18: ...Safety Precautions 17 Do Not Use Ether Starting Aids Figure 5 Do Not Use Ether Starting Aids Near Engine...
Страница 200: ...Serial Number Locations 199 Figure 190 Engine Serial Number Location Figure 191 Unit Serial Number Plate Locations...
Страница 204: ...203 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer...