ORET RONIC
™
Tramp Metal Detector
R E C 4 1 0 5
2 - 1 6
•
M e t a l d e ck p l a t e s o r sk i r t b o a r d s lo c a t ed w it h in 4 ft (1 . 2 m)
e i t h er si d e o f th e co i l s u p p o r t s tru c tu r e mu st b e r e mo v e d o r
r e p l a c ed wi t h n o n - me t a l li c p a r t s.
•
M e t a l c h u te s o f f e ed p o i n t s sh o u ld b e at l ea s t 8 ft ( 2 .4 m) a w ay
f r o m t h e co i l su p p o r t s t r u c t u r e.
•
M a g n e t s mu s t b e a t l ea s t 1 8 f t (5 . 5 m) a w ay f ro m t h e c o i l
s u p p o r t s t r u c t u r e .
•
C o r r u g a t ed me t a l c o v e r s l o c a t ed w ith in 4 ft (1.2 m) ei th er si d e
o f t h e co i l s u p p o r t s t r u c t u r e mu st b e r e mo v e d o r r ep l ac e d w ith
n o n - me t a l li c co v e r s.
T h e co n t ro l u n i t e n clo s u r e sh o u l d b e mo u n t e d i n a v i b r a t i o n - f r e e a r e a l e s s
t h an 1 0 f t ( 3 m) f r o m t h e co i l ( s ) an d sh o u l d b e p r o t e c t ed f r o m e x ce s s i v e
h e a t, co ld , o r mo i st u r e.
S e e t h e F i n a l A s s e mb l y d r a w i n g s a n d t he I n s t a l l at i o n P l a c e me n t d r a w i n g s i n
A p p en d ix D o f th i s ma n u al fo r ad d i ti o n a l in s t a ll a ti o n c o n si d er a t io n s.
2.2.2 Electrical
Specifications
•
1 1 5 /2 3 0
V A C
, +1 0 %, – 1 5 %
•
5 0 / 6 0 H z
•
S i n g l e p h as e , 3 0
V A
, 0 .25
A
2.2.3 Input
Power Requirements
•
S w i t ch s el ec t a b l e: 1 1 5
V A C
o r 2 3 0
V A C
•
F u s i n g : 1 1 5
V A C
(
F
1 ) - 3 /8
A
, 2 5 0
V A C
,
S B
, “Ty p e T ”
2 3 0
V A C
(
F
1 ) - 3 /1 6
A
, 2 5 0
V A C
,
S B
, “ T y p e T ”
2.2.4 Safety
Precautions
WARNING
High voltage that may be present on leads could
cause electrical shock.
Disconnect incoming power at mains before
beginning any installation or wiring procedures.
Use extreme caution when testing in, on, or around
the electronics, PC boards, or modules. There are
voltages in excess of 115 V or 230 V in these areas.
Covers over the electronics should always remain in
place during operation. Remove only for
maintenance procedures with the machine’s power
OFF. Replace all covers before resuming operation.
WARNING
Use only the procedures and new parts specifically
referenced in this manual to ensure specification
performance and certification compliance.
Unauthorized procedures or parts can render the
Содержание Ramsey ORETRONIC III
Страница 1: ...Operating and Service Manual Ramsey ORETRONIC Tramp Metal Detector Rec 4105 Rev E Part No 060298 ...
Страница 2: ...ORETRONIC Tramp Metal Detector ...
Страница 10: ...ORETRONIC Tramp Metal Detector REC 4105 vi THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 12: ...ORETRONIC Tramp Metal Detector REC 4105 viii THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 18: ...REC 4105 xiv THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 32: ...ORETRONIC Tramp Metal Detector REC 4105 1 14 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ......
Страница 96: ...ORETRONIC Tramp Metal Detector REC 4105 4 28 THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 110: ...ORETRONIC Tramp Metal Detector REC 4105 A 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 120: ...Oretronic III Tramp Metal Detector REC 4105 B 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 124: ...Oretronic III Tramp Metal Detector REC 4105 C 4 THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 143: ......