background image

Solar Boiler™ Installation Manual (OG-300),  page  8  of  14

IN.410.06.DEC/99

Switch opens when
set point is reached

Set point control.
Set at 80°C (180°F)

Important:  Disconnect ALL wires from 
thermostat before connecting the wire from 
the Solar Boiler™.

+ PV module

– PV module

Solar storage tank
top thermostat

Limit Control

Reset button

Solar Boiler™
terminal block

LCB (red)

LCB (white)

16
17

IN (RED)

OUT (BLUE) 
on pump

Rear view of the Solar Boiler™

vent tube

pressure relief  

valve

Solar Boiler™ cover

3/8" copper 
tube 

3/8" copper tube
(marked with 
tape) 

insulation  

Connect to terminal block

The Solar Boiler™ module is precharged with the heat transfer fluid.


Remove the plugs from the brass fittings and retain. Replace with the nuts provided.  Turn the nuts on
until finger tight.

Insert the marked copper tube in the fitting located on the pump until it bottoms.  Using two wrenches,
one on the fitting body and one on the nut, tighten the nut exactly one full turn.

Repeat the above procedure for the other copper tube, which connects to the "IN"
(red) port under the pump.

Important:  Do not over tighten the nuts.  Failure to follow this procedure could
result in a leaky connection and/or cracked nut.

Connect the photovoltaic module (PV) and solar storage tank thermostat to the
Solar Boiler™ terminal block as shown in the diagram.   

Note:  Not all tanks

have the same thermostat as shown in the diagram.  Please refer to your tank
owners manual for a schematic of the thermostat.

Set the top thermostat of the solar storage tank at 80

°

C

(180

°

F).  Note:  Some thermostats have a high limit which

is less than 80

°

C.  If so, set the thermostat to its maximum.

Do not set the thermostat higher than 80

°

C.

CAUTION:  NEVER CONNECT ANY OTHER WIRES
OR SOURCES OF ELECTRICITY TO THE SOLAR
STORAGE TANK THERMOSTATS!!!  NO A/C POWER
IS TO BE CONNECTED TO THIS THERMOSTAT

Solar Boiler™ Start up


Pressurize the solar storage tank by opening the main cold
water supply valve and a hot water tap (near the Solar
Boiler™ if possible).

As the solar storage tank fills with water, air will escape
through the open hot water tap.    Check for leaks.

When the solar storage tank is full, close the hot water tap.

Ensure that the solar isolation bypass valves are in the
correct positions as indicated in step 15.

Remove the pressure relief valve and brass cap from the
Solar Boiler.  Some fluid may be visible.

Connect the wires from the photovoltaic module to the
proper screws as shown in step 16.  Ensure there is suffi-
cient sunlight. The pump will begin operation, and air
bubbling wwill be heard.

When the pump has been running for a few minutes, you
will not hear any bubbling noise from the Solar Boiler.
Place a small container under the vent tube.  Slowly, fill the
Solar Boiler with fluid until it comes out of the vent tube.

Reinstall the pressure relief valve and brass cap.  Pressurize
the system using a small pump.  Pressurize to approximately
5 psi.  (use a tire gauge to check the pressure).

Check for leaks at all LifeLine® connections.  If a leak is
observed, tighten the nut 1/4 turn.  Remember to use two
wrenches, one on the fitting body and one on the nut.

vent tube

pressure relief valve

1/4" compression
 nut

brass cap

air valve

fill tube

Содержание Solar Boiler

Страница 1: ... can cause irreparable damage and create a health and safety hazard The Solar Boiler module contains 3 75 litres 1 USgallon of heat transfer fluid when full The installation of the Solar Boiler should be inspected by a qualified technician prior to start up 1 Micro Flo solar collectors 2 Solar storage tank 3 Temperature gauge optional 4 Solar Boiler Module 5 3 4 Hard Copper Tube 6 Photovoltaic Mod...

Страница 2: ...recommended To calculate the slope of your roof measure the dimensions H and L as shown in the figure Calculate the quantity H L and compare it to the table to determine if an inclined mount is required Inclined Mount The inclined mounting kit allows the collectors to pivot in the front and uses aluminum channel to support the solar collector at the rear Instructions are provided with the rack mou...

Страница 3: ...es with silicon sealant and secure the two front clips to the roof using lag bolts Seal the perimeter of each mounting clip base with silicon Take the A solar collector and slide two 3 8 bolts in the bolt track Loosely fasten these bolts to the bottom hole of the front mounting clips using a lock washer and nut Center the solar collector so that the spacing from the end of the solar collector to t...

Страница 4: ...e through Tie a knot in the wire so that it can not be pulled out of the box Connect the black wire to the terminal and the white wire to the terminal Seal the hole in the junction box wire hole with silicon Close the junction box securely CAUTION The photovoltaic module produces electricity when exposed to sunlight To avoid any chance of shock cover the photovoltaic module with a towel during ins...

Страница 5: ...connect the Solar Boiler to the solar collectors Run the LifeLine to the solar collectors via an unused space or closet Note All LifeLine installed in the horizontal position must slope down 1 4 for every horizontal foot Secure the LifeLine at intervals of 6 feet with the clamps Do not kink the tube Do not cut the LifeLine until you are absolutely sure there is adequate length available Insulate t...

Страница 6: ...elbow to the bottom of the Solar Boiler module and position it in the direction of the solar storage tank Remove the drain valve from the solar storage tank Install the bottom tank assembly Position the tee such that one end points toward the Solar Boiler Apply teflon tape to the hose bib and attach it to the end of the tee that is pointing away from the Solar Boiler Connect the bottom of the Sola...

Страница 7: ...r storage tank Plumb the temperature pressure relief valve to a drain We recommend a plumber integrate the Solar Boiler and solar storage tank with your existing water heater AA AA AA solar storage tank AAA AAA AA 56 Flexhose rear view AA AA AA AA Flexhose 56 A A AA AA tank port 3 4 short nipple top tank tee pressure temperature relief valve hot outlet Isolation Bypass preparation Close the main c...

Страница 8: ...r storage tank at 80 C 180 F Note Some thermostats have a high limit which is less than 80 C If so set the thermostat to its maximum Do not set the thermostat higher than 80 C CAUTION NEVER CONNECT ANY OTHER WIRES OR SOURCES OF ELECTRICITY TO THE SOLAR STORAGE TANK THERMOSTATS NO A C POWER IS TO BE CONNECTED TO THIS THERMOSTAT Solar Boiler Start up Pressurize the solar storage tank by opening the ...

Страница 9: ... exchanger and hoses Reservoir Fluid Level The fluid level in the Solar Boiler reservoir should be checked every year Instructions for this procedure are part of the refilling instructions Repairs If any of the components of the Solar Boiler or Micro Flo solar collectors are damaged your local dealer or Thermo Dynamics Ltd should be advised before any repair is attempted In the case of broken glas...

Страница 10: ...hms replace with new motor check wire connections reset thermostat check thermostat relay replace thermostat use two wrenches to tighten the nut 1 4 turn use two wrenches to tighten the nut 1 4 turn disconnect photovoltaic module and contact dealer or Thermo Dynamics for assistance use two wrenches to tighten the nut 1 4 turn replace pump contact dealer or Thermo Dynamics for assistance tighten ho...

Страница 11: ...not turn the system on again until Solar Boiler is refilled The system is now drained Connect the 3 8 copper lines to the Solar Boiler unit To refill the Solar Boiler follow the instructions listed below Refilling the Solar Boiler with HTF heat transfer fluid Remove the cover from the Solar Boiler Turn the Solar Boiler off using the switch ON green OFF black located under the cover Switch only ava...

Страница 12: ...___ Comments____________________________________________________ Date ____________ Technician__________ Back Flush_________ Comments____________________________________________________ Date ____________ Technician__________ Back Flush_________ Comments____________________________________________________ For more system maintenance procedures please refer to your installation manual or contact your...

Страница 13: ...s of when a component may need to be replaced Solar Collectors 35 years Photovoltaic Module 25 years LifeLine Tubing 50 years Solar Boiler Module c w DC Motor 15 years Pump 15 years Heat Exchanger 50 years Linear Current Booster 50 years Solar Boiler Module SBM 9DC Solar Boiler Module SBM 9DC S32A Solar Collector S32A Solar Collector S32B Solar Collector Photovoltaic Module Photovoltaic Module The...

Страница 14: ...l regulations 3 HEALTH HAZARD DATA EYE May cause slight transient eye irritation Corneal injury is unlikely SKIN CONTACT Essentially nonirritating to skin on prolonged contact Repeated exposure may cause slight flaking tenderness and softening of skin SKIN ABSORPTION A single prolonged skin exposure is not likely to result in absorption of harmful amounts INGESTION Single dose oral toxicity is ext...

Отзывы: