ECO ULTRA Electric Boiler
Installation, Use and Care Manual
(Revision June 2017)
, Page
29.
Figure 16: Electrical panel - ECO ULTRA 12 kW
Figure 17: Electrical panel - ECO ULTRA 15 to 24 kW
4 poles contactor
24Vac
ZEL100-4P50A24
Transformer 208/240V x
24Vac
ZEL400- 20842440 (40VA)
UltraSmart controller
ZEL100-ULTRA
Hi-Limit automatic reset
switch
ZEL200-L6C732
Power Relay
24Vac
ZEL100-24ACNO30
Fuse
ZEL250-TDMIDJ5
4 poles contactor
24Vac
ZEL100-4P50A24
Transformer 208/240V x
24Vac
ZEL400- 20842440 (40VA)
UltraSmart controller
ZEL100-ULTRA
Hi-Limit automatic reset
switch
ZEL200-L6C732
Power Relay
24Vac
ZEL100-24ACNO30
Fuse
ZEL250-TDMIDJ5