Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature :
32°C D.B. / 23°C W.B.
■
Cooling Minimum conditions
Outdoor temperature : –15°C D.B.
Room temperature : 10°C D.B. / 6°C W.B.
■
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature :
27°C D.B.
■
Heating Minimum conditions
Outdoor temperature : –15°C D.B.
Room temperature : 5°C D.B.
OPERATING LIMITS
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
– Low voltage no. 2014/35/UE.
(Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010
+ A15:2011).
– Electromagnetic compatibility no. 2014/30/UE, 92/31 EEC and 93/68 EEC.
(Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
– Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
– Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer’s installation
and/or operating instructions.
Power Supply:
220 - 240 V ~ 50 Hz
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 8
1
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
Tools required for installation (not supplied)
Model Combinations:
SEE CATALOGUE
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas
with a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
Dear heating engineer,
we would like to congratulate you on having recommended a split system air conditioner AFIN AP: a modern product
that's capable of ensuring maximum comfort over time with a high degree of reliability, efficiency, quality and safety.
While your technical skills and knowledge will certainly be more than sufficient, this booklet contains all the
information that we have deemed necessary for the device's correct and easy installation.
Please accept our thanks and our congratulations on your choice of product.
T
5
ENGLISH