![thermital 20109806 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/thermital/20109806/20109806_installation-and-maintenance-manual_1104132052.webp)
52
ENGLISH
Checking and replacing the storage cylinder
anode
Proceed as follows to check the condition of the magnesium
anode:
- Remove the front panel (1);
- Close the DHW circuit shut-off cock;
- Connect a plastic hose to the hose union and empty
the storage cylinder through the storage cylinder drain
cock;
- Remove the insulation from the storage cylinder flange;
- Remove the magnesium anode (2) using a suitable box
spanner;
- Check the magnesium anode for wear and replace it if
necessary.
1
2
External cleaning
Clean the boiler’s casing panels and control panel with a soft
cloth damped in soapy water.
To remove marks from the boiler casing, use a cloth damped in
a 50% mix of water and denatured alcohol or a suitable clean-
ing product.
Wipe the boiler dry after cleaning it.
a
Do not use abrasive products, petrol or triethylene.
Extraordinary cleaning
Cleaning the storage cylinder
The storage cylinder should be serviced once a year to check
the condition of the internal parts and the magnesium anode
Perform the following operations before beginning any clean-
ing:
- Remove the front panel (1);
- Close the DHW circuit shut-off cock;
- Connect a plastic hose to the hose union and partly
empty the storage cylinder through the storage cylinder
drain cock;
- Remove the insulation from the storage cylinder flange;
- Pull the sensors out of their sockets;
- Remove the screws (2) fixing the flange (3) in place,
and remove the flange;
1
2
3
- Clean inside the storage cylinder and remove any resi-
dues through the access hole;
- Check the magnesium anode (4) for wear (Replace if
necessary.);
- Check the condition of the sensor holders (5);
- Check the condition of the seal (6).
5
4
6
On completion of cleaning, refit all removed parts in the re-
verse order, taking care to ensure the efficiency of the seals.
b
Push the storage cylinder sensor fully into its socket.
NOTE
Tighten the fixing nuts, proceeding diagonally around
the flange to apply pressure uniformly around the seal.