Where the appliance is installed to penthouses flue terminal should be minimum 40 cm above
the roof. In such cases the roof must be insulated with non-combus ble material.
g.
Roof ghtness must be fully ensured with ver cal flue applica ons. In case where ghtness
cannot be ensured any failure or damage which may arise is out of warranty claim.
f.
Maximum length of the flue connec on is 5 m. Maximum length is shortened by 1 meter for each
addi onal 90° elbow and 0,5 meter for each addi onal 45° elbow.