background image

 

Heating 

time 

increased  

THE  is  covered 

with a layer of sludge  

Remove  the  flange  and 

clean the THE  

Supply voltage decreased

 

Contact power main operation 

service  

 

Frequent  tripping 

of thermal switch 

The  set  tempera-

ture is close to the limit 

Set  lower  value  of  water 

heating temperature  

 

Thermostat tube is cov-

ered with sludge 

 

Take  out  the  EWH  the  re-

movable  flange  and  gently 
clean the tube from scale 

EWH operates but is not 

heating water   

Valve (Fig. 1, p.8)  

is not closed or out of 

order     

  

Close or replace the valve (Fig. 1, 

p. 8)    

Powered EWH does not 

heat water. No backlights 

of indicator lamps. 

1) no voltage in electric 

network; 

2) damaged power cord. 

3)  Thermal  switch  ac-
tuated and not switched 
on   

 

1) Check voltage at the electrical 

outlet; 

2) Contact a qualified service cen-

ter. 

3) Disconnect from the power 
supply, remove EWH protective 
cover, press the button on ther-
mal switch until you hear a click 
(fig. 2) install the cover and turn 
on the power  

 

These faults are not defects of EWH and shall be fixed by the consumer or by a 

specialized organization at his own expense.

 

In case of failure to fix problems using the above recommendations or in case of 

others  problems  revealing  you  should  contact  the  authorized  service  center  listed  in 
the operation manual

 

PRESS 

 

Figure 2. 

Thermal switch arrangement diagram

 

 

 

Содержание IF 100 H (pro)

Страница 1: ...gned to provide with hot water for domestic and industrial facilities having a cold water supply line pressure of not less than 0 05 MPa and not more than 0 7 MPa EWH shall be operated indoors in heat...

Страница 2: ...the inner tank Figure 1 p 17 The control panel in all models is on the front side of the EWH Figure 1 p 16 Tubular heating element THE thermostat and thermal switch sensors are mounted on the removabl...

Страница 3: ...with pressure exceeding 0 7 MPa To connect EWH to the water supply without safety valve To drain water from EWH with power switched on To use spare parts not recommended by the manufacturer To use wat...

Страница 4: ...at least 30 cm for all mod els In order to avoid damage of the user s and or third parties property in the event of a faulty hot water system it is required to install EWH in spaces with waterproofing...

Страница 5: ...recommended to supply water to EWH through filter installed on the cold water main not included in the scope of supply Do not use used flexible feed pipes Do not operate the EWH without safety valve...

Страница 6: ...operation it is recommended to install drain valve Fig 1 p 4 in accordance with Fig 1 for models not equipped with drainage pipe not in the scope of EWH supply If the water pressure exceeds 0 7 MPa a...

Страница 7: ...2 p 5 on the control panel Mode 2 kW is accompanied by the indication of a control lamp Turbo Figure 2 p 9 1 3 kW is accompanied by the indication of a control lamp Optimal Figure 2 p 8 and 0 7 kW is...

Страница 8: ...upply inlet or discharge valve a rubber hose sending the other end down the drain Open hot water tap on mixer and drain water from the EWH through the hose Remove the protective cover disconnect wires...

Страница 9: ...water No backlights of indicator lamps 1 no voltage in electric network 2 damaged power cord 3 Thermal switch ac tuated and not switched on 1 Check voltage at the electrical outlet 2 Contact a qualif...

Страница 10: ...erated When disposing of the EWH comply with local environmental laws and guidelines The manufacturer reserves the right to make changes to the design and specifications of the heater without prior no...

Страница 11: ...nection The manufacturer shall not be liable for defects due to violations of principles of in stallation operation and maintenance of EWH set forth herein including in cases where these defects have...

Отзывы: