It is required regularly (at least once a month) to discharge a small amount of wa-

ter through the exhaust pipe of the safety valve into the drain to remove lime deposits 
and to test the operating functionality of the valve. Handle (Fig. 1, p. 15) is intended to 
open the valve. It is necessary to control when operating water heater this handle to be 
in position closing water draining from the tank. 

5.

 

SPECIFYING SECURITY MEASURES   

Electrical safety and corrosion protection of EWH are guaranteed only if there is 

an  effective  grounding  in  accordance  with  applicable  electric  installation  rules  and 
regulations. 

Plumbing pipes and fittings shall conform to parameters of water main and have 

the required certificates of quality. 

When installing and operating EWH the following is not allowed: 

• 

To power EWH if EWH is not filled with water.  

• 

To remove the protective cover when the power is on. 

• 

Use EWH without grounding or use water pipes as grounding. 

• 

To connect EWH to water supply with pressure exceeding 0.7 MPa. 

• 

To connect EWH to the water supply without safety valve.  

• 

To drain water from EWH with power switched on. 

• 

To use spare parts not recommended by the manufacturer. 

• 

To use water from the EWH for cooking. 

• 

To use water containing impurities (sand, small stones), which might lead to 

EWH and safety valve breakdown.  

• 

To modify design and installation dimensions of EWH brackets.  

Ambient temperature shall be within the range of 3º

С

 to 40º

С

. Water in freezing 

EWH at negative temperatures results in malfunction, which is not a warranty case. 

Attention should be paid to children so that they do not play with EWH. 
EWH is not intended for use by persons (including children) with limited 
physical, sensory or mental capabilities, or by persons who do not know 
how  to  use  the  EWH,  except  for  cases  when  this  happens  under  the 
supervision or instructions by persons responsible for safety of the EWH.     

  

During EWH operation, it shall be inspected regularly for proper health (absence 

of  dripping,  burning  smell,  wiring  sparks,  etc.).  In  the  case  of  long  interruptions  in 
water heater operation,  water  supply  failures, EWH  shall be disabled and cold  water 
inlet valve shall be shut off.    

Содержание IF 100 H (pro)

Страница 1: ...gned to provide with hot water for domestic and industrial facilities having a cold water supply line pressure of not less than 0 05 MPa and not more than 0 7 MPa EWH shall be operated indoors in heat...

Страница 2: ...the inner tank Figure 1 p 17 The control panel in all models is on the front side of the EWH Figure 1 p 16 Tubular heating element THE thermostat and thermal switch sensors are mounted on the removabl...

Страница 3: ...with pressure exceeding 0 7 MPa To connect EWH to the water supply without safety valve To drain water from EWH with power switched on To use spare parts not recommended by the manufacturer To use wat...

Страница 4: ...at least 30 cm for all mod els In order to avoid damage of the user s and or third parties property in the event of a faulty hot water system it is required to install EWH in spaces with waterproofing...

Страница 5: ...recommended to supply water to EWH through filter installed on the cold water main not included in the scope of supply Do not use used flexible feed pipes Do not operate the EWH without safety valve...

Страница 6: ...operation it is recommended to install drain valve Fig 1 p 4 in accordance with Fig 1 for models not equipped with drainage pipe not in the scope of EWH supply If the water pressure exceeds 0 7 MPa a...

Страница 7: ...2 p 5 on the control panel Mode 2 kW is accompanied by the indication of a control lamp Turbo Figure 2 p 9 1 3 kW is accompanied by the indication of a control lamp Optimal Figure 2 p 8 and 0 7 kW is...

Страница 8: ...upply inlet or discharge valve a rubber hose sending the other end down the drain Open hot water tap on mixer and drain water from the EWH through the hose Remove the protective cover disconnect wires...

Страница 9: ...water No backlights of indicator lamps 1 no voltage in electric network 2 damaged power cord 3 Thermal switch ac tuated and not switched on 1 Check voltage at the electrical outlet 2 Contact a qualif...

Страница 10: ...erated When disposing of the EWH comply with local environmental laws and guidelines The manufacturer reserves the right to make changes to the design and specifications of the heater without prior no...