CODE REMATCH
1.
Wireless Transmitter has been synchronized with the Thermometer/Receiver at ex-factory setting and serialized to match. If rematch is
needed, turn off the Thermometer/Receiver, press and hold [MODE] and turn on the thermometer after 5 seconds. Rematch mode will
start and “Syn” icon will appear in the display.
2.
Turn off the Wireless Transmitter press and hold [ ] for 3 seconds; Blue LED light above power button will flash 2 times. Now turn on
the Wireless Transmitter by press and hold [ ] for 5 seconds to start rematch.
3.
The units will restore the new code automatically and return to NORMAL <Current/Min/Max> display mode.
NOTE
1.
If the Thermometer/Receiver is not in use for a long period of time remove the batteries from battery compartment to avoid battery
leakage.
2.
Do not operate the Thermometer/Receiver in environmental temperature lower than 0
o
C/32
o
F or higher than 50
o
C/122
o
F otherwise
incorrect readings or damage to the Thermometer/Receiver may result. The Thermometer/Receiver should never be placed in an
appliance for temperature monitoring, only the Probe or Wireless Transmitter.
Measuring Range
0~50°C / 32~122°F (thermometer internal sensor)
-50°C~70°C / -58~158°F (External probe sensor)
-40°C~50°C / -40~122°F (External wireless sensor)
Display Accuracy
±0.5°C / ±0.9°F in -20 ~50°C / -4~122°F, ±1.0°C / ±1.8°F rest range
Display Resolution
0.1°
Display Reading Update
10 seconds thermometer internal sensor; 30 seconds external wireless
sensor
Wireless Sensor Distance
50m (open field), 10m (inside appliance)
Battery
1.5 volt, type AAA x 4 pieces
Display Size
(W) 79mm x (H) 66mm
Thermometer Receiver Battery Life ~ 15,000 hours in probe mode
~ 4,000 hours in wireless mode
Wireless Transmitter Battery Life
~ 6,000 hours
Accessories
1 each, external probe sensor, 1m cord
4 each, AAA batteries
1 each, external wireless sensor
ERROR SYMBOLS
SYMBOL
DESCRIPTION
ACTION
r
Transmitter low battery voltage
Replace battery
A
Receiver low battery voltage
Replace battery
LL.L
1.
Sensor open circuit
2.
The reading exceeds lower range of
thermometer (-50°C/-58°F)
1.
Return the thermometer for evaluation/repair
2.
Adjust for reading to be in range of lower limit
HH.H
1.
Sensor open circuit
2.
The reading exceeds upper range of
thermometer (70°C/158°F)
1.
Return the thermometer for evaluation/repair
2.
Adjust for reading to be in range of upper limit
Con
Receiver is searching the signal from the
transmitter
1.
Turn on the transmitter
2.
No action required (searching when powered on)
Syn
Code rematch
No action required
FAI
Connection failure
1.
Review product is in valid distance range
2.
Power device on/off
LIMITED WARRANTY
1 year from date of distributor purchase due to manufacture defect of product functionality.