The adjacent room from which air is
taken must not have a low pressure
compared to the exterior due to a
counter draught caused by the
presence in that room of another
appliance in use or of a suction
device.
NOTICE
The product cannot be installed (except for sealed operation appliances with external ducted
combustion air intake):
•
in bedrooms or bathrooms;
•
in rooms where there are liquid fuel appliances with continuous or intermittent operation
that draw the combustion air from the room they are installed in;
•
in rooms where there are B-type gas heating appliances, with or without domestic hot
water production and interconnecting rooms;
•
where another heating appliance is installed without an independent air flow.
It is recommended to install the stove detached from any walls and/or furniture, with a
minimum clearance to allow effective aeration of the appliance and a good distribution of heat
in the room. Observe the distances from flammable or heat-sensitive objects (sofas, furniture,
wood panelling, etc..) as specified below. If particularly delicate objects are present, such as
furniture, curtains or sofas, increase the stove clearance accordingly.
A
B
If the floor is made of combustible material, it is recommended to use protection made of non-
combustible material (steel, glass...) that also protects the front from falling combusted
material during cleaning operations.
The appliance must be installed on a floor with adequate load capacity. If the existing
construction does not meet this requirement, one must take appropriate measures (for
example a load distribution plate).
WARNING
Heat-sensitive or flammable objects cannot be placed near the product. Keep such objects
at a minimum distance of 80 cm from the outermost point of the product.
Leave minimum 80 cm free space in front of the stove for loading, and cleaning of
combustion unit.
REFERENCES
FLAMMABLE OBJECTS
NON-FLAMMABLE
A
200 mm
100 mm
B
200 mm
100 mm
Содержание HYDRA PLUS