- 6 -
- 7 -
1-4 Main Component Structures
1. Gas Control Valve
• Feeds the necessary amount of gas to heat water to a set temperature, based on the
amount of water flowing in through the inlet measured by the Water Flow Sensor and
the water temperature calculation.
UP34-47R
LP/NG
4D00001
11DC0697
0
1
2
OUT2
OUT1
Main Gas Valve
Gas Valve 1
Filter
Gas Control Valve
Gas Valve 1
(No.1)
Main Gas Valve
(No.0)
Gas Valve 2
(No.2)
IN
2. Water Flow Control Valve with Sensor
* Measures the water flow as its rotor (bladed wheel) spins with the passing water.
The rotation of the rotor is detected by the sensor rotor (blade equipped with a
magnet) of the wheel and the Hall element which calculates the water quantity.
* When water flows more than water heater capacity, hot water temperature becomes
lower than the setting. The Water Flow Control Valve automatically reduces the
water flow to prevent such temperature drops.
Inlet
Main Body
Water Flow Sensor
Hall Element IC
Sealant
Valve Body
Water Flow
Control Valve
Rotor