- 44 -
- 45 -
Procedure
Illustration
- 44 -
Removing Electrode and Flame Rod
(1)
Disconnect high-voltage cord and Flame
Rod connector.
(2)Remove setscrews (2 pcs) fixing the
Electrode holder to pull the holder out.
Electrode holder setscrews(2 pcs)
Flame Rod
connector
Electrode
High-voltage cord
Removing Heat Exchanger Assy.
(1)
Remove Neutralizer and Manifold Assy.
(see previous step)
(2)Remove setscrews (2 pcs) fixing the
combustion chamber.
(3)
Remove the setscrew fixing the PCB
case.Lift the case up and pull it out.
(4)
Disconnect the following connectors:
1.
Thermal Fuse (front) 2P relay
connector.
2. Anti-Frost Heaters 2P connector from
the PCB.
3.
Fan Motor 4P connector from the
PCB.
4.
Over Heat Thermostat connectors (2
pcs) and other connected items.
Combustion chamber setscrews(2 pcs)
Over Heat Thermostat connectors(2 pcs)
Thermal Fuse relay connector