- 40 -
- 41 -
Procedure
Illustration
- 41 -
Removing Ignitor
(1)
Disconnect the high-voltage cord.
Remove the setscrew retaining the
Ignitor from Manifold Assy.
(Screw with steel washer is used for
Ignitor earthing.)
(2)Pull out the Ignitor.
(3)
Disconnect the Ignitor 2P connector.
(4)
Remove the setscrew retaining the
Ignitor.
(Attention)
When inserting the connector to the
Ignitor, marking should face downward
like the illustration.
If reverse side, it can be disconnected.
High-voltage cord
Screw with steel washer
Ignitor setscrew
Screw with steel washer
(earthing plate side)
Ignitor connector
marking
(
downward)