INSTALLATION INSTRUCTIONS
FAULT MONITOR
When installed with remote controllers the THERMANN HOT WATER UNIT HAS A SELF DIAGNOSING
FUNCTION FOR FAULTS.
When the unit does not operate correctly an error code is displayed on the remote control TEMPERATURE
DISPLAY INDICATOR.
The cause of the fault can be determined after checking the fault numbers display on the remote control
display.
DISPLAY PROBLEM
REMEDY
111
GAS BURNER FAILS TO IGNITE
CHECK GAS SUPPLY
121
LOSS OF COMBUSTION
CHECK GAS SUPPLY AND PRESSURE
141
RESIDUAL FLAME SAFETY DEVICE
CALL REECE CUSTOMER CARE
1800 080 055
311, 321, 341
THERMISTOR WIRE BREAKAGE
CALL REECE CUSTOMER CARE
1800 080 055
510, 511
GAS VALVE FAILURE
CALL REECE CUSTOMER CARE
1800 080 055
611
COMBUSTION FAN FAILURE
CALL REECE CUSTOMER CARE
1800 080 055
651
WATER FLOW CONTROL VALVE FAILURE
CALL REECE CUSTOMER CARE
1800 080 055
700, 731
PCB FAILURE
CALL REECE CUSTOMER CARE
1800 080 055
721
FALSE FLAME DETECTION
CALL REECE CUSTOMER CARE
1800 080 055
735
CASCADE COMMUNICATION FAILURE
CALL REECE CUSTOMER CARE
1800 080 055
740, 750, 760
COMMUNICATION FAILURE BETWEEN
REMOTE CONTROLS AND PCB
TURN OFF POWER AND TURN ON
AGAIN