IMPORTANT SAFETY INFORMATION
The drain line from the PTR Valve
must be installed in a continuously
downward direction in a frost free
environment.
The PTR Valve is to be operated
regularly to remove lime deposits and
to verify it is not blocked. The drain
line fitted to the PTR Valve must be left
open to the atmosphere.
DANGER – FAILURE TO OPERATE
THE PTR VALVE EASING LEVER AT
LEAST ONCE EVERY SIX MONTHS
MAY RESULT IN THE WATER HEATER
EXPLODING. CONTINUOUS LEAKAGE
OF WATER FROM THE VALVE MAY
INDICATE A PROBLEM WITH THE
WATER HEATER.
The PTR Valve should be checked by
a licensed tradesperson for adequate
performance, or replaced at intervals
not exceeding 5 years, or less in areas
where local regulations apply.
It is normal for water to drip from the
drain line fitted to the PTR Valve during
heating cycles.
Continuous leakage of water from the
PTR Valve may indicate a problem with
the water heater. This may be caused
by excessive water supply pressure, a
faulty PTR Valve or a faulty thermostat.
Turn off the water heater and contact
Customer Service on 1300 412 612
(Australia) or 0800 729 389 (New
Zealand).
OVER-TEMPERATURE ENERGY CUT-OUT:
The operation of the over-temperature
energy cut-out indicates a possibly
dangerous situation. Do NOT reset the
over-temperature energy cut-out until
the water heater has been serviced by a
licensed tradesperson.
ELECTRICAL SAFETY:
This water heater is designed for single
phase 240V a.c. supply only. The
electrical connection must comply with
Local Supply Authority Regulations and
AS/NZS 3000 (known as the Wiring
Rules). A means for disconnection must
be incorporated in the fixed wiring in
accordance with the Wiring Rules.
Any electrical covers should be removed
only by a licensed tradesperson, and
only after the electrical supply to the
water heater has been isolated.
When the supply wiring has been
connected, ensure the wires are kept
lower than the terminal block.
Excess wire is not to be looped close to
the thermostat or tank.
In addition to the Pressure &
Temperature Relief Valve, electric
storage water heaters are fitted with
a combination thermostat and over-
temperature energy cut-out.
This device must not be tampered with
or removed. Replacement of this device
must only be carried out by a licensed
tradesperson or the manufacturer.