Tools needed to install these products  

 

 

  

1.  Hammer Drill  
2.  Sprit Level  
3.  Pipe Bending equipment for refrigeration pipe  
4.  Pipe bending equipment for water pipe  
5.  Brazing torch  
6.  Flairing tool  
7.  Tape measure   
8.  Torque spanners  
9.  Pipe cutters  
10. Socket set with metric sockets  
11. Phillips 2 screwdriver   
12. Electrical terminal screwdriver   
13. Electrical crimping tool  
14. Electrical  Side cutters  
15. Trimming knife  
16. Wire strippers  
17. Hack saw  
18. Masonry drill bits for fixings 7mm and 10mm are recommended   
19. Masonry core bit for interconnecting services 75mm recommended   
20. Vacuum pump  
21. R410a Gauges  
22. Torr gauge  
23. Hex keys 4mm  
24. Adjustable spanner  
25. OFN & Regulator   
26. PPE ie gloves, glasses and steal toe protectors    

  
  

SAFETY INSTRUCTIONS  

To prevent injury to the user, other people, or property damage, the following instructions 

must be followed. Incorrect operation due to ignoring these instructions may cause harm or 
damage.   

  
Install the unit only when it complies with local regulations, by-laws and standards. Check 

the main voltage and frequency. This unit is only suitable for earthed sockets. An isolation 
switch is required for both indoor and outdoor units.   

  
The following safety precautions should always be taken into account:  

-

 

Be sure to read the following WARNING before installing the unit.  

-

 

Be sure to observe the cautions specified here as they include important items related to 
safety.  

-

 

After reading these instructions, be sure to keep it together with the manual in a handy 
place for future reference.  

  

  

  

Содержание AXAI-06M

Страница 1: ...Inverter Air Source Heat Pump Monobloc system Product Data Installation Manual AXAI 06M AXAI 09M AXAI 12M AXAI 15M TABLE OF CONTENT ...

Страница 2: ...it External Internal AXAI 06M AXAI 09M 7 The unit External Internal AXAI 12M AXAI 15M 8 Wiring Diagram 9 Electrical Wiring Diagram for the 6 9KW 9 Electrical Wiring Diagram for the 12 15KW 10 Field Wiring 11 WATER PIPE WORK 12 Checking the water circuit 12 Charging water 12 Water Flow Rates 12 INSTALLATION OF THE MAIN UNIT 13 Precautions for selecting the location 13 Installation space 13 Mounting...

Страница 3: ...ATION INTRODUCTION This manual This manual includes the necessary information about the unit Please read this manual carefully before you install the product Domestic hot water tank option An optional domestic hot water tank with integrated electrical booster heater can be connected to the unit The domestic hot water tank is available in different sizes Items inside product box Before starting ins...

Страница 4: ...AXAI 12M AXAI15M 1 ...

Страница 5: ...4 The manual 1 ...

Страница 6: ...5 OFN Regulator 26 PPE ie gloves glasses and steal toe protectors SAFETY INSTRUCTIONS To prevent injury to the user other people or property damage the following instructions must be followed Incorrect operation due to ignoring these instructions may cause harm or damage Install the unit only when it complies with local regulations by laws and standards Check the main voltage and frequency This un...

Страница 7: ... sure to use a dedicated section If the capacity of the power circuit is insufficient or there is an incomplete electrical circuit it could result in a fire or an electric shock The unit must always have an earthed connection If the power supply is not earthed you may not connect the unit Do not attempt move repair the unit yourself if you are not a LCP installer Improper movement or repair on the...

Страница 8: ...frigerant levels may cause failure of the product The installation of the unit must be level and secure To avoid vibration and or water leakage Do not put your fingers or others into the fan or evaporator The fan runs at high speed this could cause serious injury In order to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external s...

Страница 9: ...4mm2 shielded heat resistance cables 12KW 15kw used 3 core 6mm2 shielded heat resistance cables An isolator is required as part of the field wiring Power cable to the indoor unit 3 core 2 5mm2 shielded heat resistance cable An isolator is required as part of the field wiring Low voltage inter connecting cable 75mm shielded twisted pair NB all controls cable must be installed 300mm away from mains ...

Страница 10: ...9 Cycle diagram AXAI 06M AXAI 09M AXAI 12M AXAI 15M OVERVIEW OF THE UNIT External AXAI 06M AXAI 09M ...

Страница 11: ...10 Internal AXAI 06M AXAI 09M ...

Страница 12: ...11 External AXAI 12M AXAI 15M Internal AXAI 12M AXAI 15M ...

Страница 13: ...12 Wiring Diagram Electrical Wiring Diagram for the 6 9KW ...

Страница 14: ...iagram for the 12 15KW NB cable entry either top or bottom of the unit The unit Separated Power supply Model Separated Power supply Rated Current AXAI 06M 2200W 9 6A AXAI 09M 2500W 11 9A AXAI 12M 4200W 14A AXAI 15M 4400W 19A ...

Страница 15: ... a dedicated power supply Never use a power supply shared by another appliance Be sure to establish an earth Do not earth the unit to a utility pipe surge absorber or telephone earth Incomplete earth may cause electrical shock Be sure to install an earth leakage protector Failure to do so may cause electrical shock Wiring overview The table below gives a wiring overview of required field wiring AX...

Страница 16: ...ake sure the automatic air purge valve is open at least 2 turns 3 Fill with water until the water manometer indicates a pressure of approximately 2 0 bar Remove air in the circuit as much as possible using the air purge valves Air present in the water circuit might cause malfunctioning of the optional backup heater 4 Backup heater Check that the backup heater vessel is filled with water by opening...

Страница 17: ...ar a bedroom and the like so that the operation noise will cause no trouble 4 There must be sufficient space for carrying the unit into and out of the site 5 There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet 6 The site must be free from the possibility of flammable gas leakage in a nearby place 7 Install units power cords and inter unit cabl...

Страница 18: ...ation drawing It is best to screw in the foundation bolts until their length remains 20mm above the foundation surface NB Wall brackets are not supplied with the unit unless specified an installation guide is supplied within the wall brackets packaging Check before running Check before initial startup Turn off the power before connecting After installation before accessing circuit breaker please c...

Страница 19: ...ueezed 7 The refrigerant leak Check whether the machine refrigerant leakage if there is a leak contact your local dealer 8 Power voltage Check the power supply voltage on the screen the supply voltage must be consistent with the nameplate on the machine 9 Air vent valve Make sure the air vent valve is open at least 2 turns 10 The atmospheric valve After checking the atmospheric valve is opened whe...

Страница 20: ...input KW 1 34 2 2 2 8 3 52 COP W W 3 74 3 63 3 57 3 55 Power supply V Ph Hz 220 240 1 50 Max power input KW 2 2 3 2 4 4 8 Max current A 9 6 14 18 21 Max leaving water temperature without using backup heater 58 Working temperature range 20 43 Refrigerant circuit Refrigerant Type R410A Compressor Brand Q ty Type TOSHIBA 1 Inverter Rotary TOSHIBA 1 Inverter Twin Rotary Heat exchanger Type High effici...

Страница 21: ... weight Kg 98 118 135 160 Noise level dB A 50 53 60 62 NOTES Capacities and power inputs based on the following conditions Heating Water Inlet Outlet temperature 30 35 Outdoor air dry bulb wet bulb temperature 7 6 Cooling Water Inlet Outlet temperature 23 18 Outdoor air dry bulb temperature 35 Domestic Hot Water Water temperature in the tank 40 Outdoor air dry bulb wet bulb temperature 7 6 The rel...

Отзывы: