WARNING
• A main switch or other means for disconnection, having a contact separation in all
poles, must be incorporated in the fixed wiring in accordance with relevant local and
national legislation.
• Switch ‘off’ the power supply before making any connections.
• All field wiring and components must be installed by a licensed electrician and must
comply with relevant European and national regulations.
• The field wiring must be carried out in accordance with the wiring diagram supplied
with the unit and the instructions given below.
• Be sure to use a dedicated power supply. Never use a power supply shared by
another appliance.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, surge absorber, or
telephone earth. Incomplete earth may cause electrical shock.
• Be sure to install an earth leakage protector.
Failure to do so may cause electrical shock.
Wiring overview
The table below gives a wiring overview of required field wiring.
AXAI-06M
AXAI-09M
AXAI-12M
AXAI-15M
United Power supply
(outdoor power supply
must fuse down the
indoor power supply to
20 amps)
AWG9(6.63m
m
2
)*3
AWG9(6.63mm
2
)*3
AWG8(8.37m
m
2
)*3
AWG8(8.37m
m
2
)*3
Separated
Power supply
Outdoor
AWG13(4mm
2
)*3
AWG13(4mm
2
)*3
AWG11(4.mm
2
)*3
AWG11(4.mm
2
)*3
Communication cable
Twin-core twisted pair shielding (0.75mm
2
)*2
Содержание AXAI-06M
Страница 4: ...AXAI 12M AXAI15M 1 ...
Страница 5: ...4 The manual 1 ...
Страница 10: ...9 Cycle diagram AXAI 06M AXAI 09M AXAI 12M AXAI 15M OVERVIEW OF THE UNIT External AXAI 06M AXAI 09M ...
Страница 11: ...10 Internal AXAI 06M AXAI 09M ...
Страница 12: ...11 External AXAI 12M AXAI 15M Internal AXAI 12M AXAI 15M ...
Страница 13: ...12 Wiring Diagram Electrical Wiring Diagram for the 6 9KW ...