background image

 
 

WARRANTY 

 

 

International Refrigeration Products warrants that the product supplied is free from defects in 
material and workmanship. This warranty is valid as long as this product is properly handled, 
installed, operated and serviced in accordance with the Installation and Operating Instructions 
shipped with this unit, and the warranty card is completed and mailed no later than 30 days after 
date of purchase. All warranty claims must be made within one (1) year (five (5) years for 
compressor) from date of purchase (unless national regulations require a longer registration 
period). 
 
This warranty provides free replacement of defective parts only. Labor and replacement parts as a 
result of normal wear and tear are not covered under this warranty. 
 
Additional claims are excluded, unless required by national regulations. International Refrigeration 
Products Inc. is not responsible for incidental, consequential, direct, or indirect damages or 
expenses relating to the use of, or the inability to use the product for any purpose. Other implied 
warranties are excluded. 
 
This constitutes International Refrigeration Products warranty obligation and replaces any and all 
prior warranties for this product. 
 
INTERNATIONAL REFRIGERATION PRODUCTS INC. 
11325 Nations Ford Rd., Charlotte, NC 28134-8393 
(704) 504-8590 Phone (704) 504-3023 Fax 
 
Copyright 2006 IRP Inc. 
 

950-0077 

 
 
 
 

950-0077-revD                                                                        Page 16 of 16                                                                       9 May 2007 

Содержание 420-0011

Страница 1: ...WINDOW AIR CONDITIONER INSTALLATION AND OPERATION 950 0077 revD Page 1 of 16 9 May 2007 CATALOG NO PRODUCT CODE WAC10115R 420 0011 WAC12230R 420 0013 CATALOG NO PRODUCT CODE WAH8115M 420 0023...

Страница 2: ...We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions 950 0077 revD Page 2 of 16 9 May 2007 This is the safety alert symbo...

Страница 3: ...r will be installed Proper Here Installation is your responsibility Make sure you have everything necessary for correct installation Tools Needed The location should provide Flat Blade and Phillips sc...

Страница 4: ...rame Control panel area B Width 22 5 8 57 5 cm plus twice the thickness Of the wood used to build the frame Specific Electrical requirements are listed in the chart below C Wood thickness D Dimension...

Страница 5: ...supply cord is ready for operation NOTES The reset button must be pushed for proper operation The power supply cord must be replaced if it fails to trip when the test button is pressed of fails to re...

Страница 6: ...out of the cabinet Place the air conditioner on cardboard NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is NOT packing material Window Installat...

Страница 7: ...ain housing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal _______________________________________________________ Attach foam adhesive seal alon...

Страница 8: ...e hole in the curtain housing and into the lower windows sash 2 Insert one of the 10 x round head screws through hole and into lower window sash 3 Insert one of the 10 x round head screws through thre...

Страница 9: ...round wire to cabinet base with ground screw Position ground wire pointing straight up Put excess ground wire between coil and air conditioner cabinet 4 Insert front tabs of front panel into top of ca...

Страница 10: ...__ MODE ______________________________________________________ 1 Press MODE until you see the indicator light turn on for the mode you desire 2 Choose Cool Fan Only or Power Saver Cool Cools room You...

Страница 11: ...settings 1 Turn off air conditioner 2 Press TIMER Timer indicator light will flash Display will show remaining hours before air conditioner will turn on 3 Press the plus or minus button to change del...

Страница 12: ...it 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light...

Страница 13: ...movement from the fan Clicks from the thermostat cycle Vibrations or noise due to poor wall or window construction A high pitched hum or pulsating noise caused by the modern high efficiency compressor...

Страница 14: ...______________________________________________ Air conditioner seems to run too much _______________________________________________________ The current air conditioner replaced an older model The use...

Страница 15: ...17 3 52 AIRFLOW CFM MAX 310 306 310 VOLTAGE FREQ 115 VAC 60 HZ 115 VAC 60 HZ 208 230 VAC 60 HZ COOLING AMPS 9 74 11 8 2 HEATING AMPS 12 6 NA NA COOLING WATTS 972 1250 1595 HEATING WATTS 1380 NA NA PL...

Страница 16: ...rovides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional claims are excluded unless required by n...

Отзывы: