Manual 0-2748
25
SECTION 5: SERVICE
SECTION 5:
CUSTOMER/OPERATOR
SERVICE
5.01 Introduction
This section describes basic maintenance procedures per-
formable by operating personnel. No other adjustments
or repairs are to be attempted by other than Thermal
Dynamics Trained personnel.
For major troubleshooting and parts replacement pro-
cedures refer to PAK Master 100XL PLUS Power Sup-
ply Service Manual 0-2749.
5.02 General Maintenance
WARNING
Disconnect primary power to the system before dis-
assembling the torch, leads, or power supply.
To clean the unit, open the enclosure (refer to Section 5.05-
A, Opening Enclosure) and use a vacuum cleaner to re-
move any accumulated dirt and dust. The unit should
also be wiped clean. If necessary, solvents that are rec-
ommended for cleaning electrical apparatus may be used.
This schedule applies to all types of non-liquid cooled
plasma cutting systems. Some systems will not have all
the parts listed and those checks need not be performed.
NOTE
The actual frequency of maintenance may need to be ad-
justed according to the operating environment.
A. Maintenance Schedule
Daily Operational Checks or Every Six Cutting Hours:
1. Check torch consumable parts, replace if damaged
or worn.
2. Inspect torch for any cracks or exposed wires, re-
place if necessary.
3. Check plasma and secondary supply and pressure/
flow.
4. Purge plasma gas line to remove any moisture
build-up.
5. Inspect input power cable for damage or exposed
wires, replace if necessary.
Weekly or Every 30 Cutting Hours:
1. Check fan for proper operation and adequate air
flow.
2. Vacuum dust and dirt out of the entire machine.
CAUTION
Do not blow air into the power supply during clean-
ing. Blowing air into the unit can cause metal par-
ticles to interfere with sensitive electrical compo-
nents and cause damage to the unit.
Six Months or Every 720 Cutting Hours:
1. Check the in-line air filter(s), clean or replace as
required
2. Check cables and hoses for leaks or cracks, replace
if necessary.
3. Check all contactor points for severe arcing or pits,
replace if necessary.
B. Optional Dry Air Filter Element
Replacement
NOTE
The XL PLUS Power Supply shuts down automati-
cally when the Filter Element becomes completely
saturated. The Filter Element can be removed from
its housing, dried out, and reused. Allow 24 hours
for Element to dry.
1. Remove power from power supply.
2. Shut off air supply and bleed down system before
disassembly to change Filter Element.
A-02476
Filter
Element
Housing
Cover
Barbed
Fitting
Spring
Assembled Filter
Figure 5-1 Optional Dry Air Filter Replacement
Содержание PakMaster 100 XL plus
Страница 1: ...Manual No 0 2748 August 23 1999 Operating Manual A 02464 Air Plasma Cutting Power Supply ...
Страница 3: ...Purchase Date Power Supply Torch Record Serial Numbers For Warranty Purposes ...
Страница 4: ......
Страница 36: ...SECTION 5 SERVICE 30 Manual 0 2748 A 01354 Internal Fuse 0 8 Amps 600V Figure 5 4 Internal Fuse Location ...
Страница 41: ...Manual 0 2748 35 APPENDIX This Page is Blank ...
Страница 42: ...APPENDIX 36 Manual 0 2748 APPENDIX III SYSTEM SCHEMATIC A 02465 16 13 12 5 1 9 INRUSH GAS GAS SOL INRUSH 5 ...
Страница 43: ...Manual 0 2748 37 APPENDIX A 02465 OK OK TO MOVE 8 23 99 AC EC 8397 HS 08 23 99 ...
Страница 44: ...APPENDIX 38 Manual 0 2748 ...