Manual 0-2748
15
SECTION 3: INSTALLATION PROCEDURES
B. Checking Air Quality
To test the quality of air, place the RUN/SET/LATCH
switch to SET position, place a welding filter lens in front
of the torch and turn on the gas. Any oil or moisture in
the air will be visible on the lens. Do not initiate an arc!
CAUTION
Air supply must be free of oil, moisture, and other
contaminants. Excessive oil and moisture may
cause double-arcing, rapid tip wear, or even com-
plete torch failure. Contaminants may cause poor
cutting performance and rapid electrode wear.
C. Gas Connections
The gas supply is connected to the Pressure Regulator/
Filter Assembly installed on the rear of the nuit. The con-
nection is the same for compressed air or high pressure
gas cylinders.
1. Locate the 1/4 NPT to #4 (6mm) hose barbed fitting
shipped inside the Torch Spare Parts Kit.
2. If an optional air line filter is to be installed, refer to
subsection D.
3. Install the barbed fitting as shown below.
4. Tighten the barbed fitting.
5. Place an adjustable hose clamp (customer supplied),
1/4" (6.5mm) to 5/8" (15.9mm)) over the gas supply
hose.
Regulator/Filter
Assembly
1/4 NPT to #4 (6mm)
Hose Fitting
#4 (6mm) Gas
Supply Hose
Hose Clamp
A-00916
Figure 3-7 Gas Connection to Regulator/Filter
Assembly
D. Optional Air Line Filter Installation
Filtering is required when using air from a compressor to
insure that moisture and debris from the supply hose does
not enter the torch. Although the Regulator does have its
own filter, it is recommended the optional Dry Air Filter
or Two Stage Air Line Filter be installed for improved
filtering. Gas connections to optional filters are shown in
Figures 3-8 and 3-9 below.
A-02469
1/4 NPT to
#4 (6mm)
Hose Fitting
Dry Air Filter
Assembly
#4 (6mm)
Gas Supply
Hose
Hose Clamp
Figure 3-8 Gas Connection to Optional Dry Air
Filter Assembly
Two Stage Filter
Assembly
1/4 NPT to
#4 (6mm) Hose
Fitting
#4 (6mm) Gas
Supply Hose
Hose Clamp
A-00917
Figure 3-9 Gas Connection To Optional Two Stage
Filter Assembly
Содержание PakMaster 100 XL plus
Страница 1: ...Manual No 0 2748 August 23 1999 Operating Manual A 02464 Air Plasma Cutting Power Supply ...
Страница 3: ...Purchase Date Power Supply Torch Record Serial Numbers For Warranty Purposes ...
Страница 4: ......
Страница 36: ...SECTION 5 SERVICE 30 Manual 0 2748 A 01354 Internal Fuse 0 8 Amps 600V Figure 5 4 Internal Fuse Location ...
Страница 41: ...Manual 0 2748 35 APPENDIX This Page is Blank ...
Страница 42: ...APPENDIX 36 Manual 0 2748 APPENDIX III SYSTEM SCHEMATIC A 02465 16 13 12 5 1 9 INRUSH GAS GAS SOL INRUSH 5 ...
Страница 43: ...Manual 0 2748 37 APPENDIX A 02465 OK OK TO MOVE 8 23 99 AC EC 8397 HS 08 23 99 ...
Страница 44: ...APPENDIX 38 Manual 0 2748 ...