Manual 0-2748
11
SECTION 3: INSTALLATION PROCEDURES
SECTION 3:
INSTALLATION
PROCEDURES
3.01 Introduction
NOTE
Depending on how the system was ordered, some
Power Supply options may already be installed.
If option(s) have been factory installed some of the
instructions may not apply. It is recommended
that all subsections be read for general informa-
tion.
This section describes installation of the Power Supply
and connecting the Torch.
These instructions apply to the Power Supply only; in-
stallation procedures for the Torch, Options, and Acces-
sories are given in Manuals specifically provided for those
units.
The complete installation consists of:
1. Site selection
2. Unpacking
3. Connections to Power Supply
a. Input Power
b. Gas
c. Work Cable
d. Torch Leads
4. Grounding
5. Operator training
3.02 Site Selection
Select a clean, dry location with good ventilation and ad-
equate working space around all components.
NOTE
Review Important Safety Precautions (page 1) to
be sure that the selected location meets all safety
requirements.
The power supply is fan cooled by air flow through the
front panel to the rear panel. Air flow must not be ob-
structed. Provide at least 2 feet (0.6 m) in the rear and at
least 6 inches (0.15 m) on each side for clearance . Pro-
vide sufficient clearance in front of the unit to allow ac-
cess to the front panel controls (minimum 6 inches or 0.15
m).
CAUTION
Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.
3.03 Unpacking
Each component of the system is packaged and protected
with a carton and packing material to prevent damage
during shipping.
1. Unpack each item and remove all packing material.
NOTE
The Cutting Spare Parts Kit is shipped in the Torch
Leads Storage Area on the side of the Power Sup-
ply.
2. Locate the packing list(s) and use the list to identify
and account for each item.
3. Inspect each item for possible shipping damage. If
damage is evident, contact your distributor and/or
shipping company before proceeding with system in-
stallation.
3.04 Lifting Options
WARNINGS
Do not touch live electrical parts.
Disconnect input power conductors from de-ener-
gized supply line before moving unit.
This unit is equipped with one handle mounted onto the
top of the enclosure for hand carrying purposes.
WARNING
FALLING EQUIPMENT
can cause serious per-
sonal injury and equipment damage.
• Lift unit with the handle on top of the enclosure.
• Persons only of adequate physical strength should
lift the unit.
• Use hand cart or similar device of adequate capac-
ity.
Содержание PakMaster 100 XL plus
Страница 1: ...Manual No 0 2748 August 23 1999 Operating Manual A 02464 Air Plasma Cutting Power Supply ...
Страница 3: ...Purchase Date Power Supply Torch Record Serial Numbers For Warranty Purposes ...
Страница 4: ......
Страница 36: ...SECTION 5 SERVICE 30 Manual 0 2748 A 01354 Internal Fuse 0 8 Amps 600V Figure 5 4 Internal Fuse Location ...
Страница 41: ...Manual 0 2748 35 APPENDIX This Page is Blank ...
Страница 42: ...APPENDIX 36 Manual 0 2748 APPENDIX III SYSTEM SCHEMATIC A 02465 16 13 12 5 1 9 INRUSH GAS GAS SOL INRUSH 5 ...
Страница 43: ...Manual 0 2748 37 APPENDIX A 02465 OK OK TO MOVE 8 23 99 AC EC 8397 HS 08 23 99 ...
Страница 44: ...APPENDIX 38 Manual 0 2748 ...