
SERVICE TROUBLESHOOTING
20
Manual 0-2569
3. Locate your symptom in the appropriate Sub-Section.
4. Check the causes (easiest listed first) for the symptom.
5. Check the remedies listed for each cause.
6. Repair as needed being sure to verify that unit is fully
operational after any repairs.
NOTE
Many signals are transfered between Printed
Circiut Board Assemblies on Ribbon Cables. If
these cables become faulty they can then cause vari-
ous problems. Do not forget about these cables
when troubleshooting.
A. No front panel LED indicators ON; Fan and pump
not operating
1. No primary power. Refer to symptoms C and D also.
a. Check for proper three-phase power at input
terminal board
2. Faulty ON/OFF switch (SW1)
a. Disconnect primary power. Check each section
for continuity. Replace switch if necessary
3. Faulty voltage selection board
a. Refer to Section 4.05-A, Voltage Selection PC
Board Check. Replace Voltage Selection PC
Board if necessary
B. AC indicator ON; Fan or pump not operating
1. ENABLE signal not ON or faulty
a. Remote ENABLE or ENABLE at TB2 must be
ON. Refer to Section 4.05-B, Enable Circuit Test.
2. Blown fuse (F1 or F2)
a. Check and replace fuse if necessary. Refer to
Section 4.05-C, Blown Fuse (F1 or F2).
3. Faulty ON/OFF switch (SW1)
a. Disconnect primary power. Check each section
for continuity. Replace switch if necessary
4. Faulty Voltage Selection PC Board
a. Refer to 4.05-A, Voltage Selection PC Board
Check. Replace Voltage Selection PC Board if
necessary
5. Faulty motor contactor (MC1, MC2 or MC3)
a. Refer to Section 4.05-D, Motor Control Contac-
tor Check (MC1, MC2 or MC3). Replace con-
tactor if necessary
6. Parallel cable not connected (Slave Power Supply)
a. Install Parallel Cable
7. No ENABLE to Slave Power Supply
a. Refer to Section 4.05-T, Isolation PCB and Par-
allel Cable Interface
C. No indicators are on for the RC6010 or SC10
remotes.
1. No +48 vdc power to the remotes.
a. 3 amp fuse blown on the Bias PCB, replace.
b. Defective Bias PCB, Refer to Section 4.05-Q, 48
Volt Bias Test.
D. AMPS or VOLTS displays not on for RC6010 or
SC10.
1. Normal if ENABLE not on.
a. Turn on ENABLE at RC6010
b. Defective ENABLE circuit, Refer to Section 4.05-
B, Enable Circuit Test.
2. Faulty Remote Device
a. Replace as needed
E. Fuse blows at disconnect when primary power is
turned ON
1. Voltage selection busbars connected incorrectly
a. Check and correct if necessary.
2. One leg of three-phase primary connected to chassis
ground
a. Rewire input cable per Operating Manual.
3. Main transformer shorted
a. Replace main transformer
F. Fuse blows at disconnect when main contactor (W1
or W2) closes
1. Shorted input diode (D1-D6)
a. Refer to Section 4.05-E, Diode Check. Replace
diode(s) as required.
2. Switching transistor (Q1) shorted to heatsink
a. Replace Q1, check heat-sink for possible dam-
age. Refer to Section 4.05-M, Switching Con-
trol Check (Q1).
3. Shorted input capacitor (C7-C12)
a. Replace capacitor if necessary
Содержание MERLIN 6000
Страница 1: ...Manual No 0 2569 October 6 1999 MERLIN 6000 Plasma Cutting Master Power Supply Service Manual A 01497...
Страница 6: ...TABLE OF CONTENTS continued...
Страница 16: ...INTRODUCTION 10 Manual 0 2569...
Страница 66: ...REPLACEMENT PROCEDURES 60 Manual 0 2569...
Страница 71: ...Manual 0 2569 65 PARTS LISTS 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 19 18 17 20 21 A 02341 22 23 3 3 25 24 26...
Страница 82: ...PARTS LISTS 76 Manual 0 2569...
Страница 96: ...APPENDIX 90 Manual 0 2569 APPENDIX XIII CORNER SLOWDOWN CSD CIRCUIT DIAGRAM A 01140...
Страница 103: ...Manual 0 2569 97 APPENDIX APPENDIX XX ARC STARTER BOX OPTION SYSTEM SCHEMATIC A 01575...
Страница 106: ...APPENDIX 100 Manual 0 2569 APPENDIX XXII GAS CONTROL GC3000 WIRING DIAGRAM A 01129...
Страница 107: ...Manual 0 2569 101 APPENDIX...
Страница 108: ...APPENDIX 102 Manual 0 2569 APPENDIX XXIII SYSTEM SCHEMATIC Rev B or Earlier A 01573...
Страница 110: ...APPENDIX 104 Manual 0 2569 APPENDIX XXIV SYSTEM SCHEMATIC Rev C or Later A 01947...
Страница 112: ...APPENDIX 106 Manual 0 2569...